#
#   VizieR Astronomical Server vizier.u-strasbg.fr
#    Date: 2013-03-03T06:08:33 [V1.97 (28-Nov-2012)]
#   In case of problem, please report to:	question@simbad.u-strasbg.fr
#
#
#Coosys	J2000:	eq_FK5 J2000
#INFO	votable-version=1.97 (28-Nov-2012)	
#INFO	-ref=VIZ5132e0280516	
#INFO	-out.max=unlimited	
#INFO	queryParameters=33
#-oc.form=sexa
#-out.max=unlimited
#-out.add=_RAJ,_DEJ
#-sort=_r
#-nav=cat:V/137D&tab:{V/137D/XHIP}&key:source=V/137D/XHIP&HTTPPRM:&&-ref=VIZ5132e0280516&-out.max=50&-out.form=HTML Table&-out.add=_r&-out.add=_RAJ,_DEJ&-sort=_r&-oc.form=sexa&-meta.foot=1&-meta=1&-meta.ucd=2&-c.eq=J2000&-c.r=  2&-c.u=arcmin&-c.geom=r&-usenav=1&
#-c.eq=J2000
#-c.r=  2
#-c.u=arcmin
#-c.geom=r
#-source=V/137D/XHIP
#-order=I
#-out=HIP
#-out=Comp
#Comp=<0
#-out=RAJ2000
#-out=DEJ2000
#-out=pmRA
#-out=pmDE
#-out=SpType
#SpType==,B5V,B6V,B7V,B8V,B9V,B5V,B6V,B7V,B8V,B9V
#Simbad=Simbad
#-out=Imag
#-out=Jmag
#Jmag=>6.5 and <=8
#-out=e_Jmag
#-out=Hmag
#Hmag=>6.5 and <=8
#-out=e_Hmag
#-out=Kmag
#Kmag=>6.5 and <=8
#-out=e_Kmag
#-out=B-V
#-out=V-I
#	


#Name: V/137D
# Extended Hipparcos Compilation (XHIP) (Anderson+, 2012)
#Coosys	J2000_1991.250:	eq_FK5 J2000 ep=1991.250

#Name: V/137D/XHIP
# XHIP catalog: astrometry, spectrography, space motions, exoplanets, photometry, and references

#_RAJ2000     A12    u="h:m:s" UCD=pos.eq.ra        w=12  Right ascension (FK5, Equinox=J2000.0) at Epoch=J2000, proper motions taken into account (computed by VizieR, not part of the original data)
#_DEJ2000     A12    u="d:m:s" UCD=pos.eq.dec       w=12  Declination (FK5, Equinox=J2000.0) at Epoch=J2000, proper motions taken into account (computed by VizieR, not part of the original data)
#HIP          I6     u=---     UCD=meta.id;meta.main w=6   Hipparcos identifier \linkRole{details from HIP catalogs}
#Comp         a6     u=---     UCD=meta.code.multip w=6   Component(s) (1)
#RAJ2000      F12.8  u=deg     UCD=pos.eq.ra;meta.main w=12  Right ascension (ICRS, Epoch=J1991.25)
#DEJ2000      F12.8  u=deg     UCD=pos.eq.dec;meta.main w=12  Declination (ICRS, Epoch=J1991.25)
#pmRA         F8.2   u=mas/yr  UCD=pos.pm;pos.eq.ra w=8   Proper motion in RA*cos(DEdeg)
#pmDE         F8.2   u=mas/yr  UCD=pos.pm;pos.eq.dec w=8   Proper motion in Declination
#SpType       a26    u=---     UCD=src.spType       w=26  Spectral type (MK, HD, or other)
#Imag         F6.3   u=mag     UCD=phot.mag;em.opt.I w=6   ? Apparent magnitude in I
#Jmag         F6.3   u=mag     UCD=phot.mag;em.IR.J w=6   ? J selected default magnitude (22)
#e_Jmag       F6.3   u=mag     UCD=stat.error;phot.mag;em.IR.J w=6   ? J total magnitude uncertainty (22)
#Hmag         F6.3   u=mag     UCD=phot.mag;em.IR.H w=6   ? H selected default magnitude (22)
#e_Hmag       F6.3   u=mag     UCD=stat.error;phot.mag;em.IR.H w=6   ? H total magnitude uncertainty (22)
#Kmag         F6.3   u=mag     UCD=phot.mag;em.IR.K w=6   ? K selected default magnitude (22)
#e_Kmag       F6.3   u=mag     UCD=stat.error;phot.mag;em.IR.K w=6   ? K total magnitude uncertainty (22)
#B-V          F6.3   u=mag     UCD=phot.color;em.opt.B;em.opt.V w=6   ? Johnson B-V color index
#V-I          F5.2   u=mag     UCD=phot.color;em.opt.V;em.opt.I w=5   ? Color index in Cousins' system

#column-units: ---	"h:m:s"	"d:m:s"	mag	---	deg	deg	mas/yr	mas/yr	---	mag	mag	mag	mag	mag	mag	mag	mag
#column-types: INTEGER	CHAR*12	CHAR*12	REAL	REAL	DOUBLE	DOUBLE	DOUBLE	DOUBLE	DOUBLE	REAL	REAL	REAL	REAL	REAL	REAL	REAL	REAL
HIP	_RAJ2000	_DEJ2000	Imag	Comp	RAJ2000	DEJ2000	pmRA	pmDE	SpType	Jmag	e_Jmag	Hmag	e_Hmag	Kmag	e_Kmag	B-V	V-I
------	------------	------------	------	------	------------	------------	--------	--------	--------------------------	------	------	------	------	------	------	------	-----
   328	00 04 11.901	-30 08 05.69	 7.133	      	001.04953031	-30.13491797	   20.84	    1.78	B8V                       	 7.195	 0.023	 7.283	 0.034	 7.252	 0.021	-0.085	-0.07
   440	00 05 19.923	+68 53 03.95	 7.070	      	001.33276908	+68.88440928	   36.28	    9.13	B9V                       	 7.036	 0.024	 7.023	 0.036	 7.068	 0.029	-0.006	 0.01
  1550	00 19 18.742	+59 08 20.56	 7.221	      	004.82793307	+59.13904408	   33.78	   -0.02	B9V                       	 6.900	 0.020	 6.831	 0.018	 6.787	 0.016	 0.049	 0.06
  1925	00 24 17.454	+60 27 11.02	 7.489	      	006.07268463	+60.45306743	    8.05	   -3.01	B7V                       	 7.164	 0.027	 7.257	 0.059	 7.193	 0.020	 0.067	 0.08
  2058	00 26 03.682	+20 08 48.67	 6.667	      	006.51535436	+20.14683510	   -5.46	    6.86	B8V                       	 6.645	 0.020	 6.675	 0.018	 6.687	 0.018	-0.036	-0.01
  2329	00 29 47.867	+57 01 50.55	 7.518	      	007.44935662	+57.03071795	   20.44	   -3.82	B8V                       	 7.391	 0.018	 7.419	 0.020	 7.438	 0.018	 0.002	 0.02
  2371	00 30 16.381	+64 44 56.31	 7.234	      	007.56810984	+64.74898339	   25.12	   -3.22	B9V                       	 7.161	 0.021	 7.191	 0.047	 7.198	 0.021	 0.007	 0.03
  2665	00 33 48.015	-39 55 28.55	 7.398	      	008.44997937	-39.92461562	   26.14	    7.83	B9V                       	 7.432	 0.021	 7.438	 0.031	 7.413	 0.026	-0.016	 0.01
  3058	00 38 49.274	+59 49 34.15	 6.719	      	009.70521294	+59.82616124	   19.40	   -3.07	B8V                       	 6.707	 0.041	 6.738	 0.018	 6.737	 0.024	-0.019	 0.00
  3284	00 41 51.223	+38 53 46.69	 7.661	      	010.46339856	+38.89631635	   10.14	   -5.37	B9V                       	 7.644	 0.020	 7.695	 0.049	 7.704	 0.027	-0.057	-0.04
  3541	00 45 12.827	+23 35 26.84	 7.385	      	011.30344969	+23.59080500	   -1.75	   -6.66	B9V                       	 7.330	 0.027	 7.363	 0.021	 7.335	 0.018	 0.001	 0.02
  3798	00 48 48.010	+18 18 50.72	 7.886	      	012.20006467	+18.31409690	   -8.20	   -2.93	B9V                       	 7.841	 0.020	 7.874	 0.020	 7.888	 0.024	-0.004	 0.02
  3820	00 49 03.821	-42 33 42.45	 7.652	      	012.26587358	-42.56177744	   14.31	   -5.81	B8V                       	 7.758	 0.024	 7.845	 0.023	 7.862	 0.029	-0.115	-0.10
  4075	00 52 15.453	+60 05 23.81	 8.361	      	013.06439382	+60.08995078	   -1.66	   -1.47	B8V                       	 7.682	 0.023	 7.599	 0.040	 7.484	 0.016	 0.336	 0.39
  4174	00 53 19.381	+49 39 20.31	 7.093	      	013.33071106	+49.65565190	   11.53	   -3.98	B9V                       	 6.955	 0.021	 7.031	 0.018	 7.002	 0.023	-0.015	 0.01
  4437	00 56 45.669	+60 01 59.38	 7.803	      	014.19020031	+60.03317416	   17.92	   -5.89	B9V                       	 7.663	 0.018	 7.728	 0.029	 7.684	 0.023	 0.018	 0.04
  5347	01 08 22.601	+54 13 52.91	 7.033	      	017.09412501	+54.23138776	   10.54	  -10.31	B9V                       	 6.752	 0.018	 6.758	 0.017	 6.745	 0.021	 0.078	 0.09
  5370	01 08 40.873	+70 40 53.54	 7.426	      	017.17025830	+70.68157017	    6.13	  -12.91	B9V                       	 7.337	 0.020	 7.408	 0.044	 7.379	 0.016	 0.034	 0.05
  5387	01 08 55.861	+09 43 49.82	 7.330	      	017.23269926	+09.73055089	   21.86	  -18.40	B9V                       	 7.417	 0.026	 7.491	 0.031	 7.466	 0.021	-0.058	-0.04
  6270	01 20 24.643	+51 49 59.89	 7.578	      	020.10265535	+51.83331704	    5.77	   -6.03	B7V                       	 7.352	 0.019	 7.425	 0.038	 7.396	 0.020	 0.056	 0.07
  6300	01 20 52.149	+60 56 56.10	 7.548	      	020.21717417	+60.94894152	   22.81	  -10.40	B9V                       	 7.542	 0.018	 7.634	 0.042	 7.623	 0.016	-0.026	 0.00
  7064	01 31 02.475	+39 29 40.61	 7.581	      	022.76029179	+39.49462512	    7.04	   -4.75	B9V                       	 7.661	 0.043	 7.706	 0.024	 7.684	 0.020	-0.057	-0.04
  7399	01 35 24.152	+53 20 44.06	 6.847	      	023.85059780	+53.34557646	    8.34	   -2.16	B6V                       	 6.760	 0.023	 6.799	 0.024	 6.788	 0.026	-0.012	 0.01
  7625	01 38 12.636	+62 21 06.42	 6.702	      	024.55269167	+62.35178210	   -7.82	    0.75	B7V                       	 6.631	 0.026	 6.730	 0.034	 6.698	 0.020	-0.015	 0.01
  8032	01 43 10.666	+62 38 36.50	 8.152	      	025.79441203	+62.64348390	    5.71	   -5.36	B9V                       	 7.875	 0.018	 7.930	 0.069	 7.874	 0.018	 0.120	 0.13
  8108	01 44 13.739	+48 12 40.73	 6.964	      	026.05717282	+48.21134061	   19.56	  -10.77	B9V                       	 6.853	 0.021	 6.922	 0.044	 6.866	 0.021	 0.027	 0.04
  8357	01 47 42.309	+54 00 16.14	 7.470	      	026.92628237	+54.00451042	    1.70	  -10.67	B7V                       	 7.488	 0.019	 7.503	 0.027	 7.555	 0.024	-0.059	-0.04
  8445	01 48 51.884	-50 28 59.90	 7.652	      	027.21611364	-50.48334815	   18.48	   17.12	B9V                       	 7.658	 0.020	 7.691	 0.038	 7.701	 0.021	-0.048	-0.03
  8490	01 49 27.172	+26 28 21.50	 6.933	      	027.36323149	+26.47267035	   -5.92	  -12.89	B8V                       	 6.984	 0.018	 7.063	 0.020	 7.071	 0.017	-0.066	-0.04
  8609	01 51 02.576	+47 25 10.34	 7.258	      	027.76068528	+47.41957459	   12.92	  -14.84	B8V                       	 7.257	 0.026	 7.279	 0.042	 7.269	 0.017	-0.015	 0.01
  8751	01 52 34.773	-67 56 40.21	 6.786	      	028.14474488	-67.94448970	   22.08	   -5.42	B9V                       	 6.773	 0.019	 6.807	 0.033	 6.808	 0.018	-0.050	-0.03
  8896	01 54 34.238	+68 09 04.40	 7.269	      	028.64259299	+68.15125095	   10.23	  -12.04	B9V                       	 7.152	 0.020	 7.192	 0.046	 7.171	 0.021	 0.012	 0.03
  8951	01 55 18.353	+06 26 13.87	 7.531	      	028.82649068	+06.43725420	   -8.94	  -27.90	B9V                       	 7.547	 0.019	 7.633	 0.051	 7.563	 0.024	-0.020	 0.00
  9000	01 55 54.257	+62 21 48.59	 7.479	      	028.97600781	+62.36350712	   12.29	   -4.50	B9V                       	 7.221	 0.029	 7.195	 0.016	 7.189	 0.024	 0.110	 0.12
  9491	02 02 06.657	+60 17 41.54	 7.911	      	030.52769666	+60.29488532	    8.45	   -5.39	B8V                       	 7.691	 0.023	 7.726	 0.038	 7.704	 0.029	 0.076	 0.09
  9508	02 02 20.009	+46 50 33.02	 7.109	      	030.58331339	+46.84255208	   16.48	  -18.69	B9V                       	 7.102	 0.020	 7.204	 0.038	 7.161	 0.023	-0.053	-0.03
  9534	02 02 35.257	-21 57 56.79	 7.037	      	030.64691620	-21.96576984	   -4.52	   -1.65	B6V                      	 7.128	 0.019	 7.198	 0.021	 7.199	 0.021	-0.106	-0.09
  9697	02 04 43.934	-82 17 57.90	 7.970	      	031.18284857	-82.29944443	   11.45	   11.75	B9V                       	 7.863	 0.020	 7.936	 0.020	 7.932	 0.016	-0.005	 0.02
 10848	02 19 37.280	+39 50 05.80	 6.672	      	034.90525253	+39.83498136	   25.79	  -14.66	B8V                       	 6.709	 0.021	 6.783	 0.021	 6.752	 0.017	-0.082	-0.06
 11295	02 25 26.636	+60 00 19.24	 7.620	      	036.36087396	+60.00538061	   22.19	  -15.17	B5V                       	 7.538	 0.018	 7.609	 0.018	 7.605	 0.017	 0.012	 0.03
 11900	02 33 33.589	-62 35 12.13	 6.805	      	038.38984469	-62.58675044	   21.02	   19.60	B9V                       	 6.847	 0.026	 6.904	 0.018	 6.875	 0.020	-0.048	-0.03
 12218	02 37 20.841	+39 53 45.96	 6.614	      	039.33679512	+39.89612693	   12.98	  -11.36	B5V                       	 6.679	 0.023	 6.782	 0.018	 6.810	 0.016	-0.114	-0.10
 12335	02 38 51.648	+39 09 00.70	 7.804	      	039.71519797	+39.15021020	    0.87	   -6.34	B9V                       	 7.844	 0.023	 7.900	 0.026	 7.892	 0.024	-0.011	 0.01
 12377	02 39 19.630	-02 04 22.01	 7.803	      	039.83178102	-02.07277337	    4.72	   -2.44	B9V                      	 7.765	 0.020	 7.813	 0.044	 7.800	 0.021	-0.004	 0.02
 12567	02 41 36.906	+69 42 34.74	 7.577	      	040.40376474	+69.70967819	    1.38	  -11.32	B8V                       	 7.480	 0.024	 7.551	 0.034	 7.525	 0.018	 0.020	 0.04
 12991	02 47 03.668	+31 23 42.19	 7.605	      	041.76523158	+31.39512185	   18.63	  -28.33	B9V                       	 7.482	 0.026	 7.478	 0.023	 7.463	 0.023	 0.076	 0.09
 13316	02 51 22.448	-02 59 50.74	 7.765	      	042.84351877	-02.99741922	    5.55	   -3.33	B9V                      	 7.750	 0.023	 7.758	 0.063	 7.707	 0.021	 0.030	 0.05
 13629	02 55 31.564	+02 01 05.79	 6.610	      	043.88148768	+02.01829969	   11.25	  -10.17	B9V                      	 6.624	 0.019	 6.649	 0.031	 6.646	 0.023	-0.038	-0.02
 13728	02 56 48.855	+68 50 09.44	 7.594	      	044.20355925	+68.83597739	    0.74	   -8.46	B6V                       	 7.234	 0.020	 7.175	 0.040	 7.195	 0.038	 0.236	 0.26
 13774	02 57 15.403	+46 01 11.78	 7.899	      	044.31418283	+46.01994822	   -1.30	   -4.25	B5V                       	 7.741	 0.020	 7.737	 0.017	 7.669	 0.027	 0.037	 0.05
 14499	03 07 16.932	+29 07 24.21	 7.532	      	046.82055693	+29.12340886	   -2.84	   -6.59	B9V                       	 7.209	 0.024	 7.199	 0.016	 7.141	 0.023	 0.139	 0.15
 14736	03 10 18.094	-01 41 40.97	 7.313	      	047.57538747	-01.69469336	    1.60	   -8.80	B9V                      	 7.369	 0.021	 7.471	 0.055	 7.409	 0.023	-0.010	 0.01
 14845	03 11 42.903	+52 09 48.46	 6.864	      	047.92866451	+52.16352075	   24.50	  -24.13	B9V                       	 6.806	 0.035	 6.829	 0.021	 6.831	 0.021	 0.006	 0.03
 15218	03 16 11.308	-30 49 38.89	 6.635	      	049.04704649	-30.82749263	   24.59	    9.29	B9V                      	 6.703	 0.024	 6.735	 0.031	 6.743	 0.018	-0.035	-0.01
 15259	03 16 49.096	+51 13 05.47	 7.146	      	049.20447731	+51.21824470	   23.32	  -24.07	B9V                       	 6.983	 0.024	 7.026	 0.023	 6.995	 0.020	 0.036	 0.05
 15832	03 23 56.632	+45 31 32.15	 8.283	      	050.98596957	+45.52560896	   -0.38	   -4.62	B8V                       	 7.846	 0.023	 7.770	 0.055	 7.733	 0.024	 0.165	 0.18
 16103	03 27 26.432	+59 11 44.15	 7.791	      	051.86016289	+59.19561825	   -5.84	   -8.90	B9V                       	 7.601	 0.020	 7.605	 0.023	 7.596	 0.016	 0.109	 0.12
 16118	03 27 38.969	+49 35 59.69	 6.925	      	051.91229269	+49.59998087	   21.29	  -26.99	B9V                       	 6.892	 0.023	 6.986	 0.024	 6.959	 0.023	-0.007	 0.01
 16137	03 27 55.781	+47 44 09.35	 7.207	      	051.98233038	+47.73599518	   24.72	  -26.06	B8V                       	 7.078	 0.023	 7.136	 0.059	 7.105	 0.020	 0.038	 0.05
 16306	03 30 13.006	+68 26 00.54	 7.963	      	052.55397065	+68.43356916	   33.67	  -35.29	B8V                       	 7.938	 0.034	 7.944	 0.017	 7.957	 0.024	 0.015	 0.03
 16450	03 31 53.950	+48 44 06.53	 6.618	*     	052.97469745	+48.73521841	   25.20	  -29.00	B8V                       	 6.575	 0.024	 6.623	 0.042	 6.581	 0.020	-0.025	 0.00
 16782	03 35 58.490	+47 05 27.70	 6.876	      	053.99362947	+47.09109075	   21.98	  -26.17	B8V                       	 6.862	 0.021	 6.912	 0.018	 6.929	 0.020	-0.022	 0.00
 16962	03 38 13.057	+49 04 58.90	 7.177	      	054.55445227	+49.08303662	  -12.44	   -4.09	B7V                       	 7.178	 0.018	 7.259	 0.018	 7.273	 0.016	-0.030	-0.01
 16986	03 38 26.936	+49 12 20.44	 6.827	      	054.61218685	+49.20571519	   12.36	  -15.47	B9V                       	 6.634	 0.021	 6.624	 0.020	 6.644	 0.020	 0.033	 0.05
 17548	03 45 27.558	+47 39 37.26	 7.156	      	056.36474446	+47.66041462	   22.04	  -26.50	B9V                       	 7.157	 0.024	 7.194	 0.031	 7.191	 0.018	-0.011	 0.01
 18296	03 54 44.581	+23 12 05.72	 7.893	      	058.68574892	+23.20161005	    2.10	   -8.51	B8V                       	 7.729	 0.026	 7.771	 0.029	 7.739	 0.023	 0.048	 0.06
 18621	03 59 05.453	+27 11 50.83	 7.329	      	059.77270582	+27.19748309	    5.06	  -12.06	B9V                       	 7.024	 0.020	 7.023	 0.024	 6.994	 0.021	 0.140	 0.15
 18903	04 03 06.612	+41 55 55.46	 7.557	      	060.77755444	+41.93207503	   -1.37	   -1.16	B9V                       	 7.182	 0.023	 7.132	 0.020	 7.088	 0.016	 0.279	 0.32
 20258	04 20 30.379	+25 49 38.82	 7.612	      	065.12656556	+25.82747483	    5.07	   -9.65	B8V                       	 7.309	 0.020	 7.309	 0.027	 7.305	 0.020	 0.176	 0.19
 20421	04 22 26.504	+36 54 20.29	 7.938	      	065.61042076	+36.90565527	    3.51	   -7.71	B6V                       	 7.599	 0.019	 7.685	 0.026	 7.604	 0.017	 0.135	 0.15
 20692	04 25 56.207	+01 01 54.39	 7.390	      	066.48420779	+01.03178934	   -4.35	   -6.07	B8V                      	 7.430	 0.024	 7.492	 0.036	 7.482	 0.031	-0.057	-0.04
 20747	04 26 46.065	-06 52 56.72	 7.303	      	066.69193803	-06.88240360	    0.60	   -7.32	B9V                      	 7.279	 0.027	 7.345	 0.034	 7.303	 0.021	-0.009	 0.01
 21135	04 31 50.449	+05 45 52.02	 6.645	      	067.96016432	+05.76449647	   15.63	  -19.50	B9V                       	 6.593	 0.029	 6.644	 0.029	 6.598	 0.018	 0.006	 0.03
 21177	04 32 24.474	+00 58 48.46	 7.279	      	068.10194820	+00.98016252	   11.52	  -13.99	B8V                      	 7.315	 0.023	 7.413	 0.046	 7.372	 0.017	-0.058	-0.04
 21258	04 33 38.485	-08 15 20.39	 6.657	      	068.41037723	-08.25565083	   -9.74	   -5.20	B9V                      	 6.678	 0.018	 6.726	 0.027	 6.718	 0.018	-0.062	-0.04
 21350	04 34 52.723	+18 24 48.25	 7.859	      	068.71966388	+18.41341332	    6.30	   -4.60	B9V                       	 7.483	 0.020	 7.441	 0.016	 7.446	 0.027	 0.210	 0.23
 21484	04 36 50.067	-08 27 37.72	 7.086	      	069.20862669	-08.46048062	   -5.53	    1.64	B9V                      	 7.084	 0.027	 7.137	 0.026	 7.142	 0.027	-0.033	-0.01
 21522	04 37 17.068	-23 02 54.85	 7.716	      	069.32109548	-23.04861175	    7.48	   17.73	B8V                      	 7.822	 0.032	 7.926	 0.049	 7.906	 0.021	-0.087	-0.07
 21576	04 37 59.164	-20 41 16.83	 7.339	      	069.49651615	-20.68802842	    0.22	    8.40	B6V                      	 7.476	 0.026	 7.596	 0.055	 7.558	 0.024	-0.115	-0.10
 21640	04 38 52.520	-08 13 29.45	 7.257	      	069.71877887	-08.22480343	   22.84	  -17.88	B9V                      	 7.261	 0.023	 7.299	 0.038	 7.296	 0.038	-0.010	 0.01
 21700	04 39 32.989	+43 39 33.11	 8.227	      	069.88746411	+43.65920347	   -2.58	   -3.06	B6V                       	 7.761	 0.023	 7.717	 0.057	 7.585	 0.021	 0.235	 0.26
 21737	04 40 04.585	+52 29 10.36	 7.913	      	070.01910575	+52.48621270	   -0.76	   -1.08	B7V                       	 7.702	 0.018	 7.732	 0.034	 7.730	 0.017	 0.073	 0.08
 21774	04 40 36.156	+44 05 49.43	 7.301	      	070.15063282	+44.09709054	    5.41	  -10.83	B8V                       	 6.905	 0.021	 6.935	 0.057	 6.857	 0.018	 0.172	 0.19
 22169	04 46 09.491	-11 33 40.32	 7.691	      	071.53953918	-11.56122034	    3.19	    7.83	B9V                      	 7.709	 0.027	 7.747	 0.059	 7.773	 0.031	-0.048	-0.03
 22172	04 46 12.067	+26 02 07.79	 7.410	      	071.55025561	+26.03559032	    8.60	  -38.60	B8V                       	 6.894	 0.019	 6.869	 0.040	 6.788	 0.021	 0.289	 0.33
 22343	04 48 39.439	+03 38 57.42	 7.352	      	072.16430024	+03.64927621	   12.41	    2.39	B8V                      	 7.401	 0.020	 7.488	 0.021	 7.455	 0.021	-0.057	-0.04
 22985	04 56 44.728	-04 46 51.94	 7.949	      	074.18637396	-04.78109030	   -2.53	   -1.14	B9V                      	 7.966	 0.018	 7.969	 0.029	 7.996	 0.026	-0.017	 0.01
 23201	04 59 35.627	+25 48 26.94	 7.892	      	074.89844128	+25.80749972	    1.41	   -7.24	B6V                       	 7.095	 0.018	 7.002	 0.020	 6.878	 0.027	 0.393	 0.46
 23348	05 01 18.362	+45 26 46.59	 7.959	      	075.32652675	+45.44627805	   -4.90	   -1.30	B9V                       	 7.813	 0.023	 7.828	 0.038	 7.816	 0.031	 0.028	 0.04
 23473	05 02 44.553	+03 27 27.74	 7.364	      	075.68563322	+03.45771426	    2.17	   -3.77	B9V                       	 7.506	 0.021	 7.604	 0.040	 7.575	 0.034	-0.093	-0.07
 23477	05 02 46.648	+46 39 36.89	 7.707	      	075.69432912	+46.66028757	   10.04	  -16.55	B9V                       	 7.580	 0.018	 7.631	 0.051	 7.581	 0.023	 0.019	 0.04
 23572	05 04 04.755	+38 52 11.15	 7.878	      	076.01981241	+38.86976523	   -0.63	   -1.00	B8V                       	 7.388	 0.017	 7.316	 0.020	 7.308	 0.023	 0.250	 0.28
 23834	05 07 26.270	-08 39 11.35	 7.066	      	076.85947911	-08.65316209	   -8.30	    4.37	B8V                       	 7.188	 0.034	 7.304	 0.053	 7.270	 0.029	-0.104	-0.09
 24099	05 10 34.118	-11 38 55.11	 7.166	      	077.64218573	-11.64863533	  -11.12	   -2.91	B9V                      	 7.215	 0.023	 7.272	 0.038	 7.271	 0.027	-0.057	-0.04
 24212	05 11 57.293	-10 57 39.60	 7.573	      	077.98873757	-10.96100731	   -6.11	    2.49	B9V                      	 7.537	 0.027	 7.604	 0.047	 7.550	 0.026	 0.001	 0.02
 24974	05 20 55.161	-21 02 23.62	 7.704	      	080.22986772	-21.03989758	  -12.25	    1.58	B8V                      	 7.810	 0.023	 7.877	 0.047	 7.894	 0.026	-0.106	-0.09
 25025	05 21 28.433	-01 32 46.45	 7.148	      	080.36847528	-01.54623523	   -1.65	   -0.76	B8V                       	 7.229	 0.024	 7.315	 0.057	 7.266	 0.026	-0.079	-0.06
 25111	05 22 34.483	+16 48 14.22	 7.963	      	080.64367968	+16.80395685	    0.31	   -2.59	B8V                       	 7.778	 0.027	 7.769	 0.017	 7.725	 0.026	 0.303	 0.35
 25157	05 23 00.172	+29 43 44.39	 7.979	      	080.75069894	+29.72906663	    6.81	  -28.44	B8V                       	 7.879	 0.018	 7.883	 0.029	 7.894	 0.016	 0.030	 0.05
 25465	05 26 44.831	-36 35 05.46	 7.218	      	081.68681418	-36.58488971	   -6.45	   15.95	B9V                      	 7.282	 0.020	 7.375	 0.033	 7.318	 0.021	-0.050	-0.03
 25557	05 27 45.766	-02 08 43.71	 7.613	      	081.94068693	-02.14546993	    2.79	   -1.88	B8V                      	 7.781	 0.034	 7.861	 0.031	 7.907	 0.029	-0.136	-0.13
 25742	05 29 47.498	+12 16 14.27	 7.088	      	082.44791829	+12.27064209	   -3.40	   -4.95	B6V                       	 7.135	 0.023	 7.221	 0.023	 7.215	 0.026	-0.088	-0.07
 25889	05 31 36.088	-61 32 28.05	 7.257	      	082.90037541	-61.54115134	   -1.89	   10.54	B8V                       	 7.331	 0.021	 7.405	 0.033	 7.422	 0.024	-0.104	-0.09
 25903	05 31 43.839	-49 01 06.48	 7.506	      	082.93266309	-49.01849102	   -0.61	    9.82	B6V                       	 7.674	 0.026	 7.751	 0.055	 7.688	 0.018	-0.111	-0.10
 25969	05 32 27.567	+26 58 53.69	 6.992	      	083.11486715	+26.98162978	   -1.25	  -19.78	B7V                       	 6.616	 0.023	 6.613	 0.029	 6.561	 0.021	 0.132	 0.15
 26024	05 33 08.908	+03 07 51.93	 7.647	      	083.28711104	+03.13109216	    2.37	   -0.40	B5V                      	 7.780	 0.020	 7.858	 0.026	 7.839	 0.029	-0.100	-0.08
 26034	05 33 15.535	+32 17 21.65	 6.618	      	083.31470386	+32.28940610	    8.60	  -24.56	B9V                       	 6.605	 0.018	 6.684	 0.018	 6.658	 0.017	-0.031	-0.01
 26185	05 34 55.487	-31 41 40.14	 7.397	      	083.73122042	-31.69448264	   -8.19	   -0.82	B9V                      	 7.415	 0.032	 7.515	 0.055	 7.470	 0.034	-0.051	-0.03
 26210	05 35 09.206	-00 16 10.57	 7.578	      	083.78835645	-00.26960069	    1.04	   -0.31	B8V                      	 7.757	 0.052	 7.823	 0.053	 7.840	 0.031	-0.116	-0.10
 26581	05 39 02.401	-05 11 40.08	 7.676	      	084.76000249	-05.19445630	    1.34	   -4.30	B5V                      	 7.827	 0.026	 7.863	 0.051	 7.890	 0.023	-0.120	-0.11
 26585	05 39 04.271	+37 58 35.92	 7.448	      	084.76781060	+37.97664598	   -4.17	   -0.69	B8V                       	 7.294	 0.020	 7.309	 0.020	 7.302	 0.018	 0.043	 0.06
 26601	05 39 15.153	+30 09 02.01	 7.497	      	084.81317090	+30.15056356	  -11.99	   -1.97	B9V                       	 7.232	 0.020	 7.220	 0.020	 7.169	 0.020	 0.114	 0.20
 26621	05 39 30.471	-40 41 02.55	 7.638	      	084.87690022	-40.68406903	   19.57	   11.79	B8V                       	 7.289	 0.020	 7.163	 0.027	 7.101	 0.018	 0.389	 0.45
 26648	05 39 49.085	+01 29 30.22	 6.923	      	084.95451060	+01.49173965	    4.64	   -5.31	B8V                       	 6.987	 0.021	 7.076	 0.023	 7.043	 0.023	-0.065	-0.04
 27027	05 43 58.589	+54 51 53.37	 6.967	      	085.99416737	+54.86486607	  -10.59	  -17.22	B8V                       	 6.991	 0.019	 7.061	 0.021	 7.099	 0.027	-0.049	-0.03
 27480	05 49 07.781	+04 12 44.90	 7.837	      	087.28243667	+04.21250000	   -5.81	  -11.72	B9V                      	 7.856	 0.021	 7.916	 0.044	 7.899	 0.021	-0.054	-0.03
 27510	05 49 32.654	-00 40 54.69	 7.642	      	087.38606060	-00.68185260	   -1.54	   -2.86	B8V                      	 7.663	 0.020	 7.737	 0.042	 7.747	 0.020	-0.061	-0.04
 27676	05 51 32.979	+28 05 31.73	 8.117	      	087.88740773	+28.09216317	    1.03	   -6.67	B9V                       	 7.944	 0.019	 7.960	 0.018	 7.943	 0.021	 0.010	 0.03
 27829	05 53 19.023	+20 17 56.78	 6.726	      	088.32926652	+20.29913113	   -1.85	  -10.56	B9V                       	 6.701	 0.021	 6.759	 0.017	 6.770	 0.020	-0.057	-0.04
 28207	05 57 35.967	-41 06 17.31	 7.797	      	089.39987503	-41.10484982	   -4.29	   16.74	B9V                       	 7.086	 0.023	 6.727	 0.033	 6.596	 0.027	 0.072	 0.08
 28374	05 59 39.616	+21 36 15.21	 6.911	      	089.91504947	+21.60426749	    7.36	  -17.69	B9V                       	 6.924	 0.021	 7.008	 0.029	 7.033	 0.016	-0.060	-0.04
 28509	06 01 05.617	+16 59 29.22	 7.619	      	090.27343264	+16.99148016	  -10.47	  -12.38	B9V                       	 7.599	 0.018	 7.665	 0.023	 7.642	 0.017	 0.019	 0.04
 28973	06 06 51.891	-11 10 24.94	 6.774	      	091.71621828	-11.17359658	   -2.10	    1.20	B5V                      	 6.960	 0.024	 7.065	 0.038	 7.094	 0.024	-0.152	-0.15
 29101	06 08 17.398	+03 23 18.18	 7.606	      	092.07250543	+03.38839184	   -6.35	   -3.57	B9V                       	 7.575	 0.027	 7.547	 0.040	 7.574	 0.023	-0.028	-0.01
 29138	06 08 47.031	+08 40 09.95	 6.563	      	092.19596247	+08.66945782	    0.59	  -11.10	B9V                       	 6.589	 0.023	 6.595	 0.036	 6.596	 0.026	-0.065	-0.04
 29165	06 09 07.182	-15 42 05.88	 7.691	      	092.27993808	-15.70164952	   -4.98	    6.71	B8V                      	 7.671	 0.023	 7.717	 0.040	 7.698	 0.020	-0.028	-0.01
 29275	06 10 16.623	-15 03 33.88	 6.950	      	092.56928305	-15.05942437	   -8.38	    5.35	B8V                      	 7.031	 0.044	 7.032	 0.038	 7.069	 0.034	-0.076	-0.06
 29298	06 10 36.741	+03 52 18.20	 7.872	      	092.65309674	+03.87172191	   -3.62	   -0.30	B5V                      	 7.573	 0.020	 7.572	 0.027	 7.553	 0.020	 0.138	 0.15
 29481	06 12 41.683	+51 41 10.84	 7.841	      	093.17365953	+51.68640634	    5.39	  -25.92	B9V                       	 7.576	 0.023	 7.524	 0.016	 7.511	 0.024	 0.168	 0.18
 29497	06 12 55.504	-08 43 44.62	 6.947	      	093.23127290	-08.72904352	   -3.03	   -7.70	B9V                      	 7.010	 0.026	 7.093	 0.034	 7.069	 0.016	-0.070	-0.05
 29546	06 13 33.479	-29 23 44.67	 6.593	      	093.38953120	-29.39574582	  -12.81	    1.49	B7V                      	 6.709	 0.020	 6.814	 0.029	 6.798	 0.024	-0.105	-0.09
 29635	06 14 41.942	-73 37 35.43	 6.615	      	093.67475575	-73.62656466	    0.51	   22.97	B8V                       	 6.527	 0.021	 6.593	 0.033	 6.529	 0.018	-0.038	-0.02
 29657	06 14 54.684	-08 48 15.21	 7.268	      	093.72786495	-08.80422395	   -5.24	    0.03	B8V                      	 7.355	 0.023	 7.426	 0.040	 7.428	 0.021	-0.094	-0.08
 29715	06 15 31.829	+00 50 05.93	 7.431	      	093.88262966	+00.83498949	   -3.90	   -3.60	B8V                      	 7.536	 0.027	 7.650	 0.044	 7.622	 0.026	-0.106	-0.09
 29780	06 16 13.868	+05 06 50.97	 7.175	      	094.05779066	+05.11417104	   -3.10	   -5.40	B8V                       	 7.153	 0.029	 7.209	 0.040	 7.166	 0.020	-0.070	-0.05
 29791	06 16 21.077	+01 04 49.25	 6.652	      	094.08781459	+01.08035559	    2.03	   -3.70	B7V                       	 6.626	 0.018	 6.663	 0.033	 6.652	 0.024	-0.058	-0.04
 29907	06 17 49.791	-64 01 48.79	 7.554	      	094.45745762	-64.03025518	    0.82	   15.24	B9V                       	 7.599	 0.021	 7.680	 0.033	 7.635	 0.027	-0.069	-0.05
 29922	06 17 58.685	+00 13 29.11	 7.720	      	094.49452921	+00.22476079	   -3.92	   -3.06	B9V                       	 7.786	 0.019	 7.852	 0.055	 7.804	 0.036	-0.023	 0.00
 30088	06 19 57.368	-13 59 34.88	 6.671	      	094.98905387	-13.99302772	   -8.70	    2.80	B9V                      	 6.669	 0.027	 6.705	 0.026	 6.695	 0.020	-0.026	 0.00
 30159	06 20 46.850	-24 18 00.57	 7.518	      	095.19520465	-24.30016184	    2.14	    1.85	B8V                      	 7.597	 0.023	 7.688	 0.036	 7.727	 0.017	-0.113	-0.10
 30180	06 21 00.778	+14 42 17.36	 7.400	      	095.25323656	+14.70486155	    2.37	  -16.15	B6V                       	 7.551	 0.037	 7.577	 0.036	 7.619	 0.018	-0.100	-0.08
 30197	06 21 10.845	-04 21 00.17	 7.910	      	095.29520056	-04.35003935	   -5.03	   -2.76	B9V                      	 7.882	 0.026	 7.931	 0.055	 7.909	 0.033	-0.035	-0.01
 30199	06 21 11.289	-44 45 30.88	 7.779	      	095.29706763	-44.75859722	   -8.50	    7.90	B7V                       	 7.897	 0.027	 7.945	 0.059	 7.961	 0.024	-0.125	-0.11
 30240	06 21 42.906	-09 40 58.46	 7.393	      	095.42879289	-09.68291410	   -6.64	    3.16	B8V                      	 7.444	 0.023	 7.519	 0.046	 7.517	 0.024	-0.078	-0.06
 30356	06 23 06.111	-03 30 56.80	 7.283	      	095.77547328	-03.51577089	   -4.50	   -3.20	B5V                      	 7.409	 0.020	 7.507	 0.033	 7.517	 0.024	-0.120	-0.11
 30418	06 23 45.250	-37 00 52.53	 6.953	      	095.93854176	-37.01460302	   -0.03	    4.87	B5V                      	 7.024	 0.024	 7.106	 0.044	 7.098	 0.020	-0.096	-0.08
 30524	06 24 55.797	-63 49 41.32	 6.336	      	096.23252187	-63.82817384	   -5.97	   12.13	B6V                       	 6.523	 0.021	 6.619	 0.044	 6.624	 0.024	-0.119	-0.10
 30650	06 26 25.164	-00 46 36.27	 6.799	      	096.60483232	-00.77674095	    7.82	    0.27	B9V                      	 6.740	 0.019	 6.816	 0.057	 6.768	 0.024	-0.018	 0.00
 30730	06 27 21.602	-15 18 57.51	 7.820	      	096.84002782	-15.31598470	   -7.13	    4.03	B8V                      	 7.877	 0.021	 7.905	 0.034	 7.926	 0.021	-0.054	-0.03
 30754	06 27 45.402	-02 39 35.41	 7.835	      	096.93917985	-02.65980378	   -1.93	  -12.77	B9V                      	 7.883	 0.023	 7.943	 0.038	 7.923	 0.021	-0.030	-0.01
 30758	06 27 47.617	-04 49 28.98	 7.846	      	096.94841544	-04.82471246	   -5.41	   -1.82	B8V                      	 7.886	 0.029	 7.932	 0.029	 7.914	 0.017	-0.077	-0.06
 30798	06 28 16.767	+01 54 45.63	 6.497	*     	097.06987815	+01.91271646	   -6.60	  -16.70	B9V                      	 6.539	 0.021	 6.588	 0.049	 6.588	 0.024	-0.064	-0.04
 30832	06 28 35.937	-01 35 22.45	 7.800	      	097.14974547	-01.58959121	   -2.70	    9.07	B8V                      	 7.891	 0.027	 7.976	 0.055	 7.945	 0.034	-0.072	-0.05
 30843	06 28 39.535	-03 47 04.25	 7.886	      	097.16473395	-03.78449060	   -1.71	   -9.29	B9V                      	 7.834	 0.046	 7.864	 0.059	 7.747	 0.023	-0.024	 0.00
 30852	06 28 42.909	-06 58 12.12	 7.586	      	097.17880060	-06.97003082	   -5.70	   -1.39	B9V                      	 7.610	 0.023	 7.659	 0.038	 7.651	 0.027	-0.058	-0.04
 31115	06 31 44.859	+02 00 58.93	 7.512	      	097.93692606	+02.01637545	   -6.10	   -2.25	B8V                      	 7.528	 0.023	 7.646	 0.044	 7.603	 0.018	-0.081	-0.06
 31253	06 33 18.100	-14 48 51.23	 7.689	      	098.32542693	-14.81418136	   -4.73	  -20.30	B9V                      	 7.667	 0.023	 7.677	 0.038	 7.640	 0.026	 0.014	 0.03
 31485	06 35 37.648	+32 34 36.52	 7.801	      	098.90687894	+32.57681695	   -4.31	   -2.44	B8V                       	 7.753	 0.018	 7.827	 0.020	 7.815	 0.020	-0.060	-0.04
 31656	06 37 32.021	-08 14 08.22	 7.198	      	099.38344296	-08.23560847	   -8.24	   -3.40	B9V                      	 7.163	 0.026	 7.208	 0.057	 7.187	 0.024	-0.007	 0.01
 31686	06 37 45.824	+18 24 05.64	 7.668	      	099.44094332	+18.40157658	   -4.60	   -4.51	B8V                       	 7.700	 0.019	 7.760	 0.018	 7.791	 0.018	-0.093	-0.07
 31768	06 38 38.466	-60 10 58.90	 7.111	      	099.66029158	-60.18305233	   -3.31	    9.81	B6V                       	 7.131	 0.018	 7.187	 0.036	 7.174	 0.020	-0.090	-0.07
 31934	06 40 25.157	+02 33 28.73	 7.508	      	100.10482518	+02.55801228	   -0.96	  -12.60	B9V                      	 7.534	 0.020	 7.568	 0.047	 7.551	 0.040	-0.006	 0.01
 31993	06 41 07.802	-30 38 44.16	 7.250	      	100.28254722	-30.64562455	  -14.21	    9.83	B9V                      	 7.273	 0.024	 7.333	 0.051	 7.301	 0.021	-0.055	-0.03
 32059	06 41 53.865	-39 47 15.60	 7.796	      	100.47448431	-39.78767550	  -14.21	    3.53	B9V                      	 7.821	 0.019	 7.931	 0.057	 7.899	 0.026	-0.062	-0.04
 32193	06 43 14.348	-21 51 44.57	 7.372	      	100.80979938	-21.86239662	   -5.41	    6.32	B5V                      	 7.563	 0.032	 7.656	 0.049	 7.707	 0.031	-0.145	-0.14
 32348	06 45 07.228	-31 39 15.53	 7.671	      	101.28013684	-31.65432625	   -7.09	    5.16	B8V                      	 7.705	 0.018	 7.800	 0.047	 7.807	 0.021	-0.095	-0.08
 32410	06 45 59.101	+38 58 12.74	 7.279	      	101.49626891	+38.97021379	   -4.97	   -3.67	B9V                       	 7.204	 0.027	 7.253	 0.017	 7.256	 0.021	-0.033	-0.01
 32451	06 46 21.098	+18 50 15.70	 7.096	      	101.58788886	+18.83772683	    6.97	  -13.42	B9V                       	 7.094	 0.024	 7.179	 0.018	 7.170	 0.042	-0.060	-0.04
 32657	06 48 43.121	-43 48 05.36	 7.427	      	102.17969622	-43.80151164	   -7.36	    9.60	B8V                       	 7.499	 0.020	 7.635	 0.033	 7.613	 0.027	-0.115	-0.11
 32668	06 48 49.231	-34 56 12.48	 6.905	      	102.20516540	-34.93682501	  -11.79	   10.37	B9V                      	 6.908	 0.023	 6.960	 0.040	 6.956	 0.027	-0.021	 0.00
 32716	06 49 31.802	-32 32 31.93	 6.900	      	102.38251842	-32.54218413	   -2.88	   -7.14	B9V                      	 6.963	 0.024	 7.050	 0.049	 7.002	 0.020	-0.082	-0.06
 32731	06 49 40.113	-15 02 40.47	 7.520	      	102.41713466	-15.04456018	    0.62	   -6.30	B9V                      	 7.517	 0.023	 7.595	 0.059	 7.553	 0.033	 0.007	 0.03
 32781	06 50 05.860	+06 15 22.72	 7.483	      	102.52442010	+06.25631581	   -1.50	   -1.50	B8V                       	 7.478	 0.019	 7.565	 0.031	 7.520	 0.023	-0.077	-0.06
 32796	06 50 13.914	-52 48 00.04	 7.676	      	102.55799890	-52.80004287	   -5.76	   13.32	B8V                       	 7.784	 0.023	 7.860	 0.049	 7.838	 0.020	-0.091	-0.07
 32901	06 51 18.530	-03 30 49.59	 7.258	      	102.82722402	-03.51376846	   -6.06	   -2.37	B8V                      	 7.232	 0.021	 7.254	 0.042	 7.214	 0.024	-0.062	-0.04
 32910	06 51 25.983	-40 33 01.02	 7.479	      	102.85828612	-40.55026809	   -7.54	   -6.66	B9V                       	 7.503	 0.019	 7.514	 0.027	 7.550	 0.021	-0.050	-0.03
 33178	06 54 20.101	-31 48 05.84	 6.917	      	103.58379566	-31.80162522	  -14.20	    1.05	B6V                      	 7.023	 0.023	 7.115	 0.046	 7.079	 0.018	-0.110	-0.09
 33922	07 02 20.611	-42 37 56.87	 7.118	      	105.58591014	-42.63249970	   -9.49	   14.90	B5V                       	 7.263	 0.018	 7.368	 0.042	 7.382	 0.023	-0.138	-0.13
 33970	07 02 54.559	-24 34 59.21	 7.178	      	105.72734370	-24.58314653	   -4.72	   13.23	B9V                      	 7.198	 0.020	 7.292	 0.046	 7.263	 0.021	-0.068	-0.05
 34032	07 03 37.175	-02 28 27.02	 7.282	      	105.90491879	-02.47417205	   -8.83	   -0.39	B7V                       	 7.500	 0.019	 7.615	 0.033	 7.581	 0.018	-0.108	-0.09
 34099	07 04 13.567	-21 15 57.71	 7.631	      	106.05653052	-21.26602031	    0.08	   -3.66	B9V                      	 7.553	 0.026	 7.563	 0.036	 7.469	 0.020	-0.009	 0.01
 34506	07 08 58.128	-45 19 52.69	 7.039	      	107.24223540	-45.33132637	   -9.79	   10.04	B8V                       	 7.063	 0.023	 7.119	 0.026	 7.137	 0.017	-0.067	-0.04
 34725	07 11 25.174	-17 19 52.06	 6.658	      	107.85490887	-17.33113550	   -6.20	    3.10	B8V                       	 6.645	 0.021	 6.673	 0.024	 6.677	 0.023	-0.033	-0.01
 34901	07 13 15.866	-64 52 24.57	 7.381	      	108.31614518	-64.87352245	   -6.78	   12.59	B9V                       	 7.403	 0.021	 7.500	 0.034	 7.460	 0.026	-0.057	-0.04
 34955	07 13 57.938	-50 28 17.62	 6.812	      	108.49148227	-50.47162032	  -19.30	   24.00	B9V                       	 6.815	 0.024	 6.857	 0.033	 6.815	 0.026	-0.048	-0.03
 34964	07 14 02.661	-31 38 33.36	 7.702	      	108.51108865	-31.64260971	   -0.67	    3.51	B6V                      	 7.678	 0.018	 7.786	 0.038	 7.772	 0.026	-0.087	-0.07
 35057	07 14 59.186	-07 40 49.03	 7.751	      	108.74662451	-07.68029173	   -6.26	    2.45	B5V                      	 7.796	 0.030	 7.888	 0.036	 7.869	 0.023	-0.090	-0.07
 35075	07 15 11.844	-36 13 32.27	 7.447	      	108.79938349	-36.22564196	  -10.98	    5.14	B6V                      	 7.504	 0.026	 7.601	 0.040	 7.594	 0.024	-0.085	-0.07
 35162	07 16 01.915	+29 15 18.36	 7.501	      	109.00798027	+29.25512380	   -0.82	   -9.57	B8V                       	 7.540	 0.020	 7.603	 0.020	 7.637	 0.021	-0.074	-0.05
 35300	07 17 31.605	-05 49 21.50	 7.262	      	109.38171300	-05.82262948	  -11.06	   -3.43	B8V                      	 7.365	 0.020	 7.437	 0.036	 7.462	 0.029	-0.081	-0.06
 35306	07 17 35.266	-03 44 52.78	 7.482	      	109.39697312	-03.74798539	  -12.34	   -4.21	B8V                      	 7.556	 0.027	 7.642	 0.057	 7.649	 0.027	-0.140	-0.13
 35408	07 18 38.842	-63 23 12.12	 7.382	      	109.66192141	-63.38672942	  -14.90	   11.99	B9V                       	 7.420	 0.018	 7.512	 0.063	 7.471	 0.026	-0.039	-0.02
 35418	07 18 45.736	-55 16 50.04	 7.766	      	109.69059432	-55.28064407	   -6.35	   31.60	B9V                       	 7.767	 0.027	 7.819	 0.047	 7.791	 0.023	-0.026	 0.00
 35483	07 19 27.129	-37 30 23.89	 7.821	      	109.86306914	-37.50664755	  -10.21	    5.22	B9V                      	 7.875	 0.021	 7.960	 0.040	 7.899	 0.021	-0.050	-0.03
 35544	07 20 04.805	-20 42 14.74	 6.960	      	110.02003420	-20.70406562	   -4.75	  -11.38	B9V                      	 6.865	 0.020	 6.915	 0.042	 6.872	 0.031	 0.011	 0.03
 35754	07 22 30.845	-00 15 33.68	 6.804	      	110.62857331	-00.25933167	  -22.20	  -10.10	B9V                      	 6.811	 0.026	 6.826	 0.034	 6.821	 0.023	-0.053	-0.03
 35864	07 23 37.744	-14 06 00.62	 7.674	      	110.90728143	-14.10018439	   -6.12	    4.60	B8V                      	 7.530	 0.032	 7.508	 0.042	 7.400	 0.024	-0.064	-0.04
 36080	07 26 03.388	-04 32 14.55	 6.760	      	111.51412690	-04.53733373	   -4.79	  -17.11	B8V                      	 6.748	 0.020	 6.729	 0.040	 6.744	 0.020	-0.008	 0.01
 36167	07 26 59.446	-41 37 44.74	 8.042	      	111.74771673	-41.62911184	   -8.19	    7.70	B6V                       	 7.887	 0.019	 7.909	 0.034	 7.861	 0.038	 0.051	 0.06
 36179	07 27 03.772	-12 13 26.16	 7.904	      	111.76573034	-12.22393004	   -5.96	   -1.72	B8V                      	 7.873	 0.023	 7.954	 0.044	 7.921	 0.029	-0.016	 0.01
 36211	07 27 25.838	+66 19 53.65	 6.497	      	111.85767933	+66.33164170	   -3.63	  -29.30	B9V                       	 6.525	 0.020	 6.611	 0.027	 6.578	 0.023	-0.064	-0.04
 36298	07 28 17.579	-43 57 47.28	 7.601	      	112.07327510	-43.96312003	   -8.50	   -5.20	B9V                       	 7.585	 0.029	 7.598	 0.027	 7.613	 0.027	-0.051	-0.03
 36355	07 28 56.683	-34 55 06.14	 7.004	      	112.23620162	-34.91839045	   -8.15	    7.46	B5V                      	 7.124	 0.023	 7.235	 0.049	 7.161	 0.026	-0.118	-0.10
 36963	07 35 55.558	-37 26 44.67	 7.276	      	113.98151522	-37.44575794	   -7.63	    6.97	B9V                      	 7.310	 0.021	 7.451	 0.047	 7.363	 0.018	-0.071	-0.05
 37007	07 36 19.258	-69 03 23.55	 6.872	      	114.08027269	-69.05657585	   -4.30	   14.40	B8V                       	 6.777	 0.018	 6.812	 0.040	 6.722	 0.024	-0.011	 0.01
 37161	07 38 11.886	-51 38 41.41	 7.699	      	114.54955762	-51.64485302	   -8.27	    6.88	B9V                       	 7.561	 0.023	 7.537	 0.031	 7.531	 0.026	 0.037	 0.05
 37184	07 38 24.015	-39 59 31.03	 6.632	      	114.60009979	-39.99195826	  -11.83	    2.63	B9V                      	 6.615	 0.021	 6.711	 0.038	 6.640	 0.020	-0.047	-0.03
 37336	07 39 52.704	-38 32 53.88	 7.960	      	114.96962399	-38.54831069	   -7.85	    4.91	B8V                      	 7.906	 0.023	 7.943	 0.046	 7.978	 0.024	-0.039	-0.02
 37446	07 41 14.326	-39 14 10.90	 7.740	      	115.30970450	-39.23638096	   -3.80	    8.40	B9V                      	 7.732	 0.020	 7.786	 0.049	 7.795	 0.026	-0.050	-0.03
 37514	07 41 58.030	-38 31 42.09	 6.587	      	115.49184718	-38.52839437	  -17.49	   14.65	B8V                      	 6.676	 0.019	 6.766	 0.057	 6.722	 0.024	-0.087	-0.07
 37557	07 42 30.616	-39 12 04.53	 7.317	      	115.62763929	-39.20129451	  -22.56	   15.31	B9V                      	 7.353	 0.020	 7.403	 0.040	 7.356	 0.018	-0.075	-0.05
 37562	07 42 34.630	-36 22 29.33	 7.651	      	115.64432041	-36.37482213	   -9.73	    3.83	B8V                      	 7.751	 0.023	 7.830	 0.051	 7.880	 0.024	-0.107	-0.09
 37647	07 43 32.127	-04 40 50.38	 7.184	      	115.88388142	-04.68065542	   -7.94	   -1.85	B8V                      	 7.248	 0.024	 7.336	 0.046	 7.299	 0.024	-0.084	-0.06
 37697	07 44 02.498	-38 49 04.63	 7.449	      	116.01047846	-38.81799026	  -22.70	   15.44	B9V                      	 7.489	 0.023	 7.548	 0.024	 7.506	 0.020	-0.057	-0.04
 37765	07 44 40.221	-47 00 30.50	 6.785	      	116.16763317	-47.00849221	  -12.92	    8.12	B5V                       	 6.838	 0.026	 6.895	 0.038	 6.890	 0.020	-0.073	-0.05
 37838	07 45 27.365	-37 35 46.59	 7.022	      	116.36408912	-37.59631448	  -22.88	   15.73	B9V                      	 7.045	 0.021	 7.086	 0.026	 7.101	 0.016	-0.065	-0.04
 37926	07 46 19.048	-46 09 34.69	 7.607	      	116.57936684	-46.15965938	   -0.50	    9.20	B5V                       	 7.668	 0.020	 7.719	 0.040	 7.758	 0.031	-0.060	-0.04
 37961	07 46 52.853	+81 40 56.79	 7.791	      	116.72024960	+81.68247324	   -1.75	  -13.12	B8V                       	 7.095	 0.024	 6.756	 0.016	 6.597	 0.021	 0.086	 0.10
 38118	07 48 41.718	-31 37 04.11	 7.039	      	117.17387026	-31.61783731	  -15.98	   11.79	B7V                      	 7.142	 0.023	 7.228	 0.034	 7.214	 0.036	-0.106	-0.09
 38161	07 49 13.192	-10 29 57.64	 7.382	      	117.30502632	-10.49935727	  -24.94	    5.80	B9V                      	 7.309	 0.021	 7.314	 0.042	 7.275	 0.026	 0.019	 0.04
 38224	07 49 52.218	-40 54 52.35	 7.125	      	117.46758315	-40.91455912	   -2.73	    6.96	B8V                      	 7.035	 0.034	 7.129	 0.029	 7.086	 0.031	-0.070	-0.05
 38536	07 53 29.242	-61 03 16.14	 7.829	      	118.37185946	-61.05451375	   -3.47	   12.17	B8V                       	 7.673	 0.023	 7.716	 0.038	 7.659	 0.023	 0.004	 0.02
 38650	07 54 50.367	-45 39 50.77	 7.392	      	118.70990605	-45.66411573	  -11.93	    5.03	B6V                       	 7.490	 0.026	 7.620	 0.049	 7.562	 0.024	-0.100	-0.08
 38734	07 55 47.646	+10 26 36.42	 7.007	      	118.94856180	+10.44346906	  -15.39	   -8.24	B9V                       	 6.932	 0.023	 6.944	 0.047	 6.978	 0.021	-0.029	-0.01
 38887	07 57 28.018	-46 19 35.83	 7.156	      	119.36677786	-46.32662685	   -9.93	    3.05	B5V                       	 7.262	 0.023	 7.360	 0.040	 7.343	 0.018	-0.111	-0.10
 38904	07 57 42.472	-57 28 44.96	 7.357	      	119.42700008	-57.47917723	   -7.72	    8.35	B8V                       	 7.195	 0.021	 7.193	 0.042	 7.144	 0.027	 0.044	 0.06
 39107	08 00 02.969	-45 01 32.60	 7.298	      	120.01239759	-45.02574620	   -7.31	    9.43	B5V                       	 7.421	 0.018	 7.489	 0.036	 7.499	 0.023	-0.113	-0.10
 39111	08 00 05.572	-48 54 19.50	 7.375	      	120.02324521	-48.90544656	   -8.27	   11.93	B9V                       	 7.410	 0.021	 7.515	 0.047	 7.456	 0.027	-0.063	-0.04
 39458	08 03 55.464	+03 23 55.60	 7.896	      	120.98111828	+03.39878416	   -7.45	   -2.17	B9V                       	 7.883	 0.018	 7.947	 0.047	 7.924	 0.027	-0.073	-0.05
 39634	08 05 58.827	-19 53 33.05	 6.938	      	121.49514915	-19.89254999	  -13.93	   14.42	B9V                      	 6.828	 0.021	 6.856	 0.040	 6.844	 0.023	 0.015	 0.03
 39744	08 07 24.417	-60 20 55.59	 7.660	      	121.85176745	-60.34878821	   -6.47	    5.68	B8V                       	 7.579	 0.020	 7.671	 0.044	 7.603	 0.034	 0.013	 0.03
 39773	08 07 41.784	-49 00 37.68	 6.709	      	121.92416285	-49.01048517	  -16.91	    7.28	B8V                       	 6.761	 0.024	 6.840	 0.057	 6.820	 0.026	-0.080	-0.06
 39949	08 09 30.544	-59 32 29.68	 6.665	      	122.37730328	-59.54159837	   -7.57	    8.12	B5V                       	 6.802	 0.024	 6.868	 0.031	 6.881	 0.021	-0.110	-0.09
 40217	08 12 50.676	+04 55 42.67	 7.226	      	123.21117391	+04.92854945	   -9.79	  -12.76	B9V                       	 7.182	 0.021	 7.213	 0.029	 7.176	 0.023	-0.001	 0.02
 40255	08 13 18.194	-36 20 30.26	 7.396	      	123.32582917	-36.34175527	   -6.45	    6.95	B5V                      	 7.555	 0.021	 7.621	 0.040	 7.670	 0.040	-0.120	-0.11
 40410	08 14 59.540	+16 04 43.11	 7.330	      	123.74808724	+16.07864312	   -1.67	   -1.13	B9V                       	 7.350	 0.018	 7.435	 0.023	 7.422	 0.016	-0.081	-0.06
 40547	08 16 47.195	-64 24 11.37	 7.785	      	124.19668760	-64.40318675	   -7.40	   11.17	B8V                       	 7.733	 0.023	 7.794	 0.044	 7.776	 0.023	-0.022	 0.00
 40556	08 16 52.930	-64 11 13.40	 6.710	      	124.22062164	-64.18709892	  -14.47	   17.40	B8V                       	 6.715	 0.018	 6.824	 0.038	 6.783	 0.026	-0.070	-0.05
 40581	08 17 09.604	-03 21 49.41	 6.737	      	124.29003336	-03.36369714	   -7.30	  -10.93	B9V                       	 6.800	 0.019	 6.829	 0.031	 6.868	 0.020	-0.061	-0.04
 40594	08 17 16.653	-46 53 35.68	 7.498	      	124.31941260	-46.89326073	   -6.73	    6.95	B9V                       	 7.566	 0.024	 7.617	 0.040	 7.576	 0.023	-0.023	 0.00
 40742	08 18 58.305	-47 12 39.41	 7.189	      	124.74297753	-47.21094319	  -10.70	   -1.76	B8V                       	 7.253	 0.019	 7.340	 0.044	 7.343	 0.027	-0.080	-0.06
 40908	08 20 53.687	-62 23 36.44	 7.929	      	125.22370798	-62.39347653	   -1.99	    9.13	B8V                       	 7.837	 0.019	 7.920	 0.034	 7.883	 0.021	-0.028	-0.01
 40924	08 21 07.351	-34 53 38.62	 7.861	      	125.28066335	-34.89408608	  -12.18	   10.42	B9V                      	 7.861	 0.032	 7.889	 0.040	 7.883	 0.033	-0.011	 0.01
 41053	08 22 36.761	-49 03 04.63	 7.783	      	125.65322334	-49.05132256	  -13.87	   15.55	B8V                       	 7.855	 0.039	 7.899	 0.046	 7.914	 0.023	-0.060	-0.04
 41085	08 22 57.163	-43 13 40.35	 7.177	      	125.73821714	-43.22789008	  -11.60	    5.82	B5V                       	 7.157	 0.020	 7.137	 0.034	 7.047	 0.023	-0.114	-0.10
 41372	08 26 24.639	-41 11 14.02	 7.846	      	126.60268949	-41.18723599	   -7.98	    3.87	B9V                       	 7.888	 0.027	 7.924	 0.053	 7.885	 0.020	-0.038	-0.02
 41386	08 26 35.708	-49 29 49.98	 7.263	      	126.64880826	-49.49723387	   -6.30	    6.90	B8V                       	 7.301	 0.026	 7.363	 0.047	 7.287	 0.020	-0.061	-0.04
 41402	08 26 45.675	-48 57 22.34	 7.337	      	126.69035039	-48.95620002	  -10.73	   -2.78	B9V                       	 7.429	 0.023	 7.483	 0.027	 7.485	 0.024	-0.022	 0.00
 41668	08 29 43.619	-48 01 34.58	 7.748	      	127.43178013	-48.02629266	   -9.74	    7.84	B8V                       	 7.694	 0.021	 7.718	 0.031	 7.711	 0.021	-0.050	-0.03
 41729	08 30 34.201	+54 07 08.93	 6.763	      	127.64264595	+54.11918201	  -34.66	  -14.36	B9V                       	 6.714	 0.018	 6.762	 0.018	 6.752	 0.016	-0.021	-0.01
 41846	08 31 56.236	-26 42 13.34	 7.986	      	127.98435835	-26.70370311	  -15.44	   -0.54	B9V                      	 7.959	 0.021	 7.969	 0.042	 7.948	 0.027	-0.022	 0.00
 42041	08 34 11.123	-45 38 11.73	 7.612	      	128.54638772	-45.63660868	  -11.67	    6.96	B5V                       	 7.755	 0.024	 7.836	 0.046	 7.854	 0.023	-0.124	-0.11
 42121	08 35 10.123	-54 12 22.28	 7.124	      	128.79223921	-54.20622698	  -14.72	   15.77	B7V                       	 7.267	 0.026	 7.350	 0.021	 7.356	 0.020	-0.109	-0.09
 42203	08 36 18.624	-64 39 30.88	 7.873	      	129.07764433	-64.65860834	   -8.17	   12.43	B8V                       	 7.845	 0.020	 7.906	 0.029	 7.882	 0.020	-0.042	-0.02
 42236	08 36 40.340	-60 19 39.47	 7.878	      	129.16813003	-60.32764002	   -9.66	    3.88	B5V                       	 7.713	 0.120	 7.929	 0.036	 7.884	 0.023	-0.050	-0.03
 42348	08 38 01.639	-11 44 37.44	 6.590	      	129.50688403	-11.74373004	  -21.71	   -1.90	B9V                      	 6.632	 0.021	 6.673	 0.051	 6.680	 0.024	-0.044	-0.02
 42613	08 41 04.683	-66 48 58.76	 6.751	      	130.26964465	-66.81633253	  -21.64	    4.75	B8V                       	 6.808	 0.018	 6.892	 0.047	 6.888	 0.023	-0.088	-0.07
 42654	08 41 35.049	-22 11 39.58	 7.765	      	130.39610161	-22.19434366	  -24.06	    6.42	B9V                      	 7.764	 0.018	 7.830	 0.036	 7.781	 0.021	 0.013	 0.03
 42690	08 42 04.177	-74 36 33.23	 7.418	      	130.51751037	-74.60925176	  -11.52	    9.16	B8V                       	 7.414	 0.027	 7.466	 0.038	 7.477	 0.026	-0.028	-0.01
 42707	08 42 12.584	-32 13 52.84	 7.298	      	130.55246667	-32.23135131	  -11.92	    3.13	B9V                      	 7.255	 0.021	 7.285	 0.047	 7.229	 0.021	-0.024	 0.00
 42720	08 42 22.556	-46 34 45.66	 7.857	      	130.59400144	-46.57936054	   -4.97	    4.36	B9V                       	 7.886	 0.021	 7.872	 0.031	 7.865	 0.036	-0.021	 0.00
 43136	08 47 10.465	+04 21 28.77	 7.343	      	131.79359973	+04.35800084	    1.13	   -3.30	B9V                       	 7.286	 0.024	 7.328	 0.049	 7.285	 0.033	 0.017	 0.04
 43173	08 47 38.189	-24 23 37.33	 8.050	      	131.90913682	-24.39367842	   -5.59	   -9.82	B9V                      	 7.946	 0.024	 7.984	 0.047	 7.931	 0.024	 0.040	 0.06
 43303	08 49 21.261	-43 22 14.41	 7.532	      	132.33861478	-43.37068187	   -8.52	    4.75	B6V                       	 7.642	 0.018	 7.721	 0.044	 7.713	 0.027	-0.093	-0.07
 43484	08 51 26.026	-45 37 22.60	 7.736	      	132.85847399	-45.62297394	   -9.51	   12.14	B9V                       	 7.616	 0.032	 7.702	 0.029	 7.639	 0.026	 0.004	 0.02
 43566	08 52 21.773	-56 14 31.55	 7.245	      	133.09074145	-56.24211649	   -4.33	    7.61	B6V                       	 7.271	 0.024	 7.334	 0.038	 7.311	 0.018	-0.076	-0.06
 44099	08 58 55.800	-68 08 21.31	 6.953	      	134.73252469	-68.13927604	   -3.69	    9.98	B7V                       	 6.974	 0.018	 7.073	 0.031	 7.014	 0.020	-0.060	-0.04
 44192	09 00 05.951	-74 23 59.66	 6.866	      	135.02506988	-74.39994695	  -30.54	   17.49	B9V                       	 6.920	 0.018	 6.999	 0.063	 6.964	 0.020	-0.064	-0.04
 44317	09 01 31.590	-49 34 45.57	 7.517	      	135.38166986	-49.57932756	  -11.95	    0.99	B5V                       	 7.647	 0.024	 7.767	 0.042	 7.747	 0.017	-0.115	-0.10
 44423	09 03 05.332	-53 33 01.34	 6.424	      	135.77229960	-53.55039500	  -20.27	    9.38	B6V                       	 6.530	 0.029	 6.552	 0.044	 6.530	 0.020	-0.074	-0.05
 44431	09 03 08.823	-25 30 15.15	 6.725	      	135.78678639	-25.50420125	   -8.46	   -2.98	B8V                      	 6.716	 0.021	 6.786	 0.049	 6.719	 0.026	-0.033	-0.01
 44709	09 06 34.462	-47 55 09.34	 7.795	      	136.64366999	-47.91929698	  -21.97	   15.00	B9V                       	 7.806	 0.024	 7.850	 0.034	 7.858	 0.018	-0.070	-0.05
 44721	09 06 45.019	-62 50 59.49	 7.559	      	136.68768586	-62.84985826	  -20.42	    0.15	B8V                       	 7.517	 0.027	 7.571	 0.036	 7.578	 0.033	-0.045	-0.02
 44786	09 07 39.607	-68 45 17.33	 7.586	      	136.91507226	-68.75483844	   -6.42	    9.82	B6V                       	 7.652	 0.023	 7.712	 0.046	 7.702	 0.021	-0.086	-0.07
 45125	09 11 37.851	-54 02 13.27	 6.750	      	137.90778430	-54.03705142	  -16.95	   13.20	B9V                       	 6.805	 0.021	 6.881	 0.044	 6.848	 0.020	-0.052	-0.03
 45235	09 13 08.692	-53 30 17.30	 7.262	      	138.28626171	-53.50482614	  -10.87	    8.47	B9V                       	 7.307	 0.026	 7.366	 0.036	 7.378	 0.023	-0.054	-0.03
 45252	09 13 22.872	+05 48 55.89	 7.339	      	138.34532880	+05.81552875	  -11.83	   -2.11	B9V                       	 7.304	 0.021	 7.392	 0.021	 7.352	 0.016	-0.053	-0.03
 45275	09 13 39.459	-71 37 04.22	 7.763	      	138.41445303	-71.61786388	   -5.50	   10.85	B9V                       	 7.604	 0.027	 7.631	 0.061	 7.570	 0.016	 0.013	 0.03
 45372	09 14 47.455	-55 38 27.29	 7.239	      	138.69778940	-55.64093618	  -13.59	    9.31	B5V                       	 7.328	 0.026	 7.426	 0.038	 7.454	 0.029	-0.109	-0.09
 45523	09 16 40.137	-54 39 21.20	 7.917	      	139.16734629	-54.65590840	  -26.04	    7.89	B9V                       	 7.844	 0.024	 7.872	 0.042	 7.845	 0.034	 0.009	 0.03
 45754	09 19 47.935	-34 06 12.02	 6.448	      	139.94976332	-34.10331572	  -11.62	   -9.72	B8V                      	 6.551	 0.021	 6.608	 0.026	 6.606	 0.021	-0.087	-0.07
 45803	09 20 25.343	-75 42 48.33	 7.343	      	140.10563888	-75.71345628	   -4.57	   13.18	B9V                       	 7.241	 0.019	 7.266	 0.049	 7.214	 0.024	 0.048	 0.06
 45916	09 21 44.791	-02 47 34.42	 7.199	      	140.43667089	-02.79288793	  -16.38	   -3.03	B9V                      	 7.153	 0.019	 7.158	 0.031	 7.158	 0.026	-0.020	 0.00
 46054	09 23 30.270	-16 39 58.48	 7.332	      	140.87618147	-16.66625310	  -22.56	    3.59	B9V                      	 7.331	 0.024	 7.402	 0.024	 7.387	 0.021	-0.041	-0.02
 46333	09 26 47.047	-59 34 43.59	 6.561	      	141.69608194	-59.57880541	  -10.59	   12.14	B7V                       	 6.662	 0.024	 6.764	 0.040	 6.732	 0.029	-0.080	-0.06
 46789	09 32 04.191	-53 32 31.11	 7.737	      	143.01752186	-53.54198086	  -14.67	    2.60	B8V                       	 7.805	 0.020	 7.938	 0.047	 7.914	 0.021	-0.077	-0.06
 46985	09 34 34.936	-64 01 50.95	 7.425	      	143.64566451	-64.03085200	  -17.29	   13.75	B8V                       	 7.472	 0.023	 7.508	 0.049	 7.530	 0.029	-0.031	-0.01
 47119	09 36 06.750	+74 19 07.72	 6.495	      	144.02829329	+74.31887606	  -18.50	  -27.10	B9V                       	 6.582	 0.023	 6.666	 0.024	 6.663	 0.021	-0.083	-0.06
 47379	09 39 10.059	-62 33 16.02	 7.577	      	144.79199811	-62.55447454	  -15.91	    9.95	B9V                       	 7.526	 0.023	 7.575	 0.031	 7.538	 0.020	-0.005	 0.02
 47397	09 39 26.588	-54 45 12.11	 6.925	      	144.86085144	-54.75337207	  -16.42	    2.88	B5V                       	 7.036	 0.019	 7.100	 0.042	 7.110	 0.018	-0.126	-0.12
 47495	09 40 56.048	-54 59 00.35	 6.992	      	145.23360543	-54.98344225	  -16.86	    5.21	B5V                       	 7.115	 0.023	 7.195	 0.038	 7.212	 0.024	-0.110	-0.09
 47728	09 43 45.504	-76 46 02.03	 7.728	      	145.93972484	-76.76724943	  -11.94	    7.53	B9V                       	 7.383	 0.023	 7.393	 0.061	 7.316	 0.024	 0.137	 0.15
 48383	09 51 46.880	-45 09 29.19	 7.542	      	147.94539200	-45.15811473	  -16.70	    2.19	B9V                       	 7.566	 0.018	 7.627	 0.034	 7.629	 0.023	-0.050	-0.03
 48430	09 52 26.268	-71 56 36.16	 6.922	      	148.10957489	-71.94340725	  -15.87	   11.66	B8V                       	 6.889	 0.032	 6.905	 0.034	 6.896	 0.044	-0.030	-0.01
 48518	09 53 42.661	-03 51 43.23	 7.409	      	148.42778553	-03.86201363	  -12.91	    2.63	B9V                      	 7.344	 0.021	 7.406	 0.057	 7.376	 0.029	-0.020	 0.00
 48720	09 56 13.828	-53 37 09.11	 6.847	      	149.05769398	-53.61922090	  -18.56	   10.01	B7V                       	 6.904	 0.029	 6.979	 0.031	 6.959	 0.018	-0.088	-0.07
 49360	10 04 34.071	-64 38 51.82	 6.935	      	151.14204212	-64.64775932	  -14.26	   13.45	B9V                       	 7.049	 0.026	 7.080	 0.033	 7.088	 0.033	-0.059	-0.04
 49537	10 06 52.047	-51 04 39.81	 7.085	      	151.71694546	-51.07774220	  -20.91	    6.62	B9V                       	 7.029	 0.030	 7.069	 0.018	 7.016	 0.027	-0.032	-0.01
 49833	10 10 24.265	-64 23 03.22	 6.892	      	152.60119274	-64.38427557	  -15.71	   19.22	B8V                       	 6.813	 0.020	 6.849	 0.034	 6.838	 0.023	-0.020	 0.00
 49863	10 10 55.797	-59 09 15.69	 7.400	      	152.73254996	-59.15437206	  -13.60	    5.31	B9V                       	 7.265	 0.023	 7.246	 0.033	 7.229	 0.024	 0.044	 0.06
 50026	10 12 48.251	-56 09 02.77	 7.920	      	153.20113468	-56.15078591	  -20.43	    7.14	B9V                       	 7.864	 0.024	 7.923	 0.051	 7.902	 0.026	 0.022	 0.04
 50108	10 13 49.246	-68 03 35.39	 6.712	      	153.45522420	-68.05982929	   -4.99	   -0.52	B6V                       	 6.670	 0.021	 6.731	 0.051	 6.683	 0.020	-0.017	 0.01
 50437	10 17 52.791	-54 37 23.48	 7.841	      	154.47000696	-54.62317758	  -10.98	   -4.33	B9V                       	 7.813	 0.024	 7.871	 0.038	 7.863	 0.027	 0.007	 0.03
 50849	10 22 59.266	-24 20 01.24	 6.841	      	155.74688230	-24.33361792	   22.39	  -24.94	B8V                      	 6.850	 0.027	 6.843	 0.038	 6.858	 0.024	-0.053	-0.03
 51287	10 28 33.954	-06 18 11.88	 7.575	      	157.14151924	-06.30330297	  -18.53	    1.78	B9V                      	 7.583	 0.019	 7.680	 0.036	 7.639	 0.020	-0.037	-0.01
 51421	10 30 06.831	-68 33 07.29	 7.967	      	157.52849491	-68.55203538	   -4.93	    4.03	B8V                      	 7.617	 0.021	 7.602	 0.053	 7.440	 0.029	-0.029	-0.01
 51507	10 31 07.430	-67 42 08.57	 7.172	      	157.78105007	-67.70238718	  -14.44	    3.14	B9V                       	 7.060	 0.024	 7.135	 0.069	 7.032	 0.027	 0.040	 0.06
 51934	10 36 32.785	-59 11 25.19	 7.095	      	159.13667382	-59.19033475	  -14.81	    2.17	B5V                       	 7.198	 0.023	 7.318	 0.033	 7.308	 0.018	-0.104	-0.09
 52079	10 38 30.698	-70 18 35.38	 7.696	      	159.62799213	-70.30984706	  -11.90	    7.77	B6V                       	 7.754	 0.030	 7.791	 0.061	 7.817	 0.031	-0.061	-0.04
 52103	10 38 45.378	-59 15 44.71	 6.543	      	159.68914348	-59.26241959	  -14.62	    0.40	B5V                       	 6.659	 0.020	 6.725	 0.021	 6.764	 0.021	-0.098	-0.08
 52230	10 40 14.925	-47 09 36.90	 7.027	      	160.06227384	-47.16026500	  -24.66	    6.70	B9V                       	 7.043	 0.018	 7.098	 0.024	 7.121	 0.018	-0.070	-0.05
 52293	10 41 06.415	-64 28 27.77	 6.740	      	160.27682678	-64.47440676	  -17.27	   10.50	B9V                       	 6.784	 0.024	 6.811	 0.027	 6.795	 0.027	-0.049	-0.03
 52861	10 48 38.948	-61 08 37.49	 8.207	      	162.16236065	-61.14375273	  -15.10	    1.76	B8V                       	 7.679	 0.026	 7.638	 0.044	 7.520	 0.029	 0.090	 0.10
 53146	10 52 18.406	-51 48 01.05	 7.546	      	163.07681153	-51.80030475	  -30.90	    5.51	B9V                       	 7.587	 0.024	 7.624	 0.033	 7.679	 0.026	-0.057	-0.04
 53164	10 52 33.630	-64 24 50.65	 8.207	      	163.14021192	-64.41407206	  -15.23	    0.95	B6V                       	 7.936	 0.023	 7.942	 0.042	 7.907	 0.033	 0.062	 0.07
 53407	10 55 25.517	-54 04 46.59	 7.306	      	163.85642422	-54.07962376	  -24.70	    6.70	B9V                       	 7.347	 0.024	 7.377	 0.031	 7.415	 0.023	-0.068	-0.05
 53705	10 59 17.850	-10 19 31.58	 7.223	      	164.82443915	-10.32544223	  -26.30	    1.40	B9V                      	 7.206	 0.023	 7.292	 0.038	 7.225	 0.017	-0.015	 0.01
 53999	11 02 46.639	-75 35 39.27	 7.900	      	165.69450730	-75.59424874	  -18.11	    3.44	B9V                       	 7.654	 0.026	 7.648	 0.061	 7.634	 0.029	 0.086	 0.10
 54006	11 02 54.764	-72 14 32.00	 6.749	      	165.72841379	-72.24221960	  -28.88	   -0.98	B5V                       	 6.607	 0.023	 6.648	 0.036	 6.590	 0.026	 0.017	 0.04
 54026	11 03 12.836	-63 03 59.85	 7.708	      	165.80352457	-63.06663582	   -7.93	    4.56	B8V                       	 6.887	 0.024	 6.750	 0.055	 6.541	 0.018	 0.448	 0.52
 54079	11 03 57.465	-71 00 02.59	 7.823	      	165.98957927	-71.00070884	  -18.89	   -4.07	B9V                       	 7.620	 0.024	 7.590	 0.038	 7.558	 0.023	 0.060	 0.07
 54257	11 05 57.811	-76 07 48.88	 7.534	      	166.49110308	-76.13024803	  -22.24	    1.06	B7V                       	 7.154	 0.021	 7.090	 0.031	 6.970	 0.023	 0.152	 0.17
 54505	11 09 05.225	-20 30 48.79	 7.701	      	167.27184847	-20.51355571	  -30.48	    1.13	B9V                      	 7.677	 0.018	 7.763	 0.033	 7.721	 0.018	-0.006	 0.01
 54542	11 09 41.019	-54 42 53.31	 7.081	      	167.42103048	-54.71481668	  -28.24	    3.21	B8V                       	 7.190	 0.030	 7.285	 0.038	 7.230	 0.021	-0.061	-0.04
 54557	11 09 50.021	-76 36 47.72	 8.584	      	167.45863962	-76.61325382	  -20.84	   -0.57	B9V                       	 7.641	 0.026	 7.347	 0.055	 7.149	 0.020	 0.381	 0.45
 54684	11 11 40.384	-60 18 38.95	 6.664	      	167.91835710	-60.31079896	  -18.72	   -8.79	B8V                       	 6.619	 0.019	 6.669	 0.029	 6.636	 0.026	-0.025	 0.00
 54740	11 12 29.817	-71 44 57.78	 7.503	      	168.12443258	-71.74937904	  -25.19	   -1.30	B8V                       	 7.384	 0.027	 7.419	 0.063	 7.381	 0.020	 0.028	 0.04
 55342	11 20 00.529	-59 11 17.00	 7.286	      	170.00231602	-59.18805171	  -23.69	   -1.52	B9V                       	 7.145	 0.026	 7.193	 0.046	 7.126	 0.033	-0.005	 0.02
 55480	11 21 45.967	-22 06 18.89	 7.369	      	170.44159265	-22.10525585	  -24.22	    3.30	B8V                      	 7.417	 0.020	 7.485	 0.046	 7.515	 0.023	-0.061	-0.04
 55933	11 27 46.803	-72 04 12.74	 8.385	      	171.94506780	-72.07021559	   -7.18	    4.24	B8V                       	 7.971	 0.026	 7.921	 0.065	 7.902	 0.029	 0.173	 0.19
 56393	11 33 39.380	-57 38 42.36	 7.835	      	173.41419640	-57.64510574	  -24.47	    2.83	B9V                       	 7.729	 0.021	 7.777	 0.034	 7.713	 0.020	-0.001	 0.02
 57043	11 41 42.363	-71 30 22.87	 7.834	      	175.42663992	-71.50636309	  -16.53	    4.49	B9V                       	 7.540	 0.021	 7.539	 0.034	 7.521	 0.020	 0.123	 0.14
 57173	11 43 30.682	-15 02 34.17	 6.949	      	175.87793850	-15.04282721	  -38.50	    0.69	B9V                      	 6.964	 0.021	 6.987	 0.029	 6.948	 0.024	-0.054	-0.03
 57409	11 46 09.458	-73 36 14.28	 8.021	      	176.53954035	-73.60396203	  -15.37	   -1.58	B8V                       	 7.776	 0.021	 7.771	 0.029	 7.733	 0.017	 0.087	 0.10
 57451	11 46 36.396	-64 45 57.52	 6.819	      	176.65173561	-64.76597432	  -14.93	   -1.82	B8V                       	 6.584	 0.018	 6.618	 0.034	 6.543	 0.029	 0.068	 0.08
 57861	11 52 04.121	-49 24 04.10	 7.044	      	178.01724251	-49.40114232	  -19.09	    1.48	B5V                       	 7.121	 0.021	 7.248	 0.051	 7.214	 0.020	-0.100	-0.08
 58709	12 02 29.428	-69 23 38.94	 8.016	      	180.62268991	-69.39415938	  -10.67	    3.70	B9V                       	 7.895	 0.019	 7.907	 0.026	 7.841	 0.024	 0.060	 0.07
 59133	12 07 32.737	-45 34 52.17	 7.270	      	181.88649303	-45.58115942	  -25.44	    0.84	B9V                      	 7.162	 0.021	 7.197	 0.033	 7.166	 0.016	 0.015	 0.04
 59758	12 15 14.404	-73 03 39.94	 8.159	      	183.81018861	-73.06108306	  -20.73	   -4.78	B9V                       	 7.637	 0.027	 7.575	 0.036	 7.500	 0.027	 0.282	 0.32
 60041	12 18 46.079	-88 24 53.71	 6.665	      	184.69478822	-88.41494453	  -31.80	   10.42	B9V                       	 6.643	 0.019	 6.739	 0.034	 6.696	 0.026	-0.068	-0.05
 60517	12 24 21.397	-47 22 22.57	 6.637	      	186.08927741	-47.37293117	  -34.38	   -2.17	B9V                      	 6.655	 0.023	 6.708	 0.036	 6.677	 0.017	-0.049	-0.03
 61066	12 30 56.093	-75 24 02.81	 7.430	      	187.73380583	-75.40075984	   -8.78	   -7.96	B9V                       	 7.064	 0.026	 7.065	 0.029	 6.997	 0.017	 0.088	 0.10
 61193	12 32 19.727	-78 11 38.86	 7.715	      	188.08240836	-78.19411330	  -17.97	   -5.52	B5V                       	 7.559	 0.019	 7.583	 0.033	 7.573	 0.020	 0.060	 0.07
 61626	12 37 51.123	-57 51 56.16	 7.533	      	189.46306160	-57.86559912	  -10.55	   -0.74	B8V                       	 7.466	 0.021	 7.451	 0.036	 7.455	 0.020	 0.015	 0.03
 61787	12 39 50.976	-67 02 26.57	 8.071	      	189.96248334	-67.04070934	  -13.53	   -1.78	B8V                       	 7.744	 0.021	 7.751	 0.044	 7.707	 0.024	 0.095	 0.11
 62193	12 44 48.818	-64 57 51.75	 8.297	      	191.20349789	-64.96436504	  -15.77	   -3.79	B9V                       	 7.678	 0.030	 7.650	 0.055	 7.511	 0.018	 0.380	 0.44
 62483	12 48 16.470	-44 43 07.57	 6.876	      	192.06871467	-44.71875247	  -25.88	   -6.72	B9V                      	 6.820	 0.020	 6.880	 0.036	 6.819	 0.024	-0.018	 0.00
 63073	12 55 25.763	-73 58 07.21	 7.896	      	193.85744243	-73.96865152	  -11.05	   -7.26	B9V                       	 7.765	 0.020	 7.791	 0.034	 7.758	 0.033	 0.038	 0.05
 63565	13 01 34.896	-60 40 17.00	 7.316	      	195.39545807	-60.67137894	  -11.32	   -3.80	B6V                       	 7.184	 0.018	 7.215	 0.044	 7.144	 0.018	 0.059	 0.07
 63832	13 04 57.211	-57 03 21.02	 8.006	      	196.23845829	-57.05579274	  -17.44	  -19.33	B9V                       	 7.696	 0.030	 7.656	 0.033	 7.610	 0.029	 0.125	 0.14
 64501	13 13 14.180	-72 32 38.45	 8.060	      	198.30916190	-72.54400066	   -9.85	   -5.39	B6V                       	 7.946	 0.027	 7.949	 0.026	 7.937	 0.023	 0.026	 0.04
 64867	13 17 44.641	-47 35 23.74	 6.616	      	199.43609598	-47.58992437	  -25.96	   -1.42	B9V                      	 6.527	 0.026	 6.553	 0.034	 6.503	 0.026	-0.005	 0.02
 65021	13 19 43.421	-67 21 51.57	 7.247	      	199.93107068	-67.36429098	  -23.82	  -14.29	B9V                       	 7.199	 0.026	 7.291	 0.034	 7.223	 0.027	-0.010	 0.01
 65178	13 21 25.907	-43 38 03.58	 6.650	      	200.35804568	-43.63428513	  -29.88	  -17.91	B9V                      	 6.688	 0.021	 6.694	 0.023	 6.688	 0.017	-0.024	 0.01
 65628	13 27 18.499	-74 41 30.32	 6.638	      	201.82739598	-74.69172236	  -34.56	  -13.89	B9V                       	 6.666	 0.019	 6.687	 0.023	 6.746	 0.023	-0.056	-0.03
 65681	13 28 01.496	-61 03 45.04	 7.269	      	202.00629621	-61.06250028	  -12.30	   -4.05	B8V                      	 7.097	 0.027	 7.078	 0.046	 7.008	 0.023	 0.022	 0.04
 66050	13 32 30.323	-69 09 49.90	 7.958	      	203.12643050	-69.16384541	  -12.32	   -6.92	B8V                       	 7.533	 0.020	 7.528	 0.042	 7.431	 0.024	 0.188	 0.21
 66351	13 35 58.958	-73 19 38.77	 7.059	      	203.99578148	-73.32741520	  -14.41	   -8.10	B8V                       	 6.778	 0.020	 6.796	 0.046	 6.737	 0.021	 0.044	 0.06
 67302	13 47 34.197	-71 13 52.09	 6.842	      	206.89273554	-71.23109833	  -32.67	  -15.89	B9V                       	 6.830	 0.024	 6.889	 0.021	 6.886	 0.020	-0.039	-0.02
 67824	13 53 37.471	-58 26 22.86	 8.040	      	208.40616882	-58.43966656	   -8.23	   -6.73	B9V                       	 7.841	 0.021	 7.850	 0.023	 7.798	 0.027	 0.040	 0.06
 69429	14 12 55.100	-40 50 00.54	 6.744	      	213.22964220	-40.83346678	  -18.85	   -6.82	B9V                      	 6.678	 0.018	 6.709	 0.040	 6.661	 0.021	-0.012	 0.01
 69845	14 17 39.217	-40 51 42.20	 7.854	      	214.41346448	-40.86168073	  -19.28	  -17.28	B9V                      	 7.802	 0.020	 7.814	 0.034	 7.776	 0.031	-0.012	 0.01
 69871	14 17 53.071	-42 35 28.44	 7.049	      	214.47119131	-42.59120836	  -19.30	  -10.00	B9V                      	 7.019	 0.023	 7.032	 0.036	 7.003	 0.024	-0.038	-0.02
 70455	14 24 43.916	-40 45 18.59	 6.990	      	216.18305151	-40.75511263	  -21.34	  -20.59	B8V                      	 7.031	 0.020	 7.073	 0.042	 7.078	 0.023	-0.053	-0.03
 70465	14 24 47.313	-45 12 14.24	 7.857	      	216.19719479	-45.20392050	  -17.14	  -14.08	B9V                      	 7.766	 0.023	 7.786	 0.021	 7.740	 0.021	 0.028	 0.04
 70503	14 25 19.680	-72 37 14.84	 7.763	      	216.33212528	-72.62074330	  -15.62	  -18.96	B9V                       	 7.649	 0.026	 7.670	 0.049	 7.644	 0.034	 0.010	 0.03
 70626	14 26 49.873	-39 52 26.35	 6.409	      	216.70787097	-39.87393342	  -20.44	  -22.06	B9V                      	 6.528	 0.023	 6.603	 0.040	 6.592	 0.018	-0.088	-0.07
 70690	14 27 30.708	-47 05 56.58	 7.652	      	216.87801554	-47.09901321	  -18.34	  -14.77	B9V                      	 7.659	 0.024	 7.729	 0.049	 7.691	 0.029	-0.031	-0.01
 70703	14 27 39.427	-46 12 06.74	 7.672	      	216.91432889	-46.20184888	  -13.68	   -9.86	B9V                      	 7.619	 0.030	 7.649	 0.036	 7.649	 0.026	-0.022	 0.00
 71327	14 35 10.707	-46 27 43.07	 6.878	      	218.79465636	-46.46194756	  -12.44	   -7.27	B9V                      	 6.801	 0.029	 6.816	 0.036	 6.825	 0.033	-0.010	 0.01
 71538	14 37 54.884	-48 01 24.81	 6.643	      	219.47874467	-48.02353155	  -17.04	  -10.65	B8V                      	 6.603	 0.023	 6.677	 0.038	 6.634	 0.017	-0.010	 0.00
 72278	14 46 51.213	-27 14 53.96	 8.105	      	221.71397134	-27.24812845	 -214.30	  -79.56	B9V                      	 7.792	 0.027	 7.843	 0.063	 7.803	 0.023	 0.032	 0.05
 72403	14 48 13.061	-66 26 20.57	 7.669	      	222.05444979	-66.43902496	   -4.83	   -9.70	B6V                       	 7.676	 0.018	 7.710	 0.031	 7.713	 0.046	-0.022	 0.00
 72713	14 51 58.543	-60 20 05.07	 7.790	      	222.99393251	-60.33470465	   -0.49	  -14.71	B9V                       	 7.512	 0.021	 7.531	 0.034	 7.477	 0.021	 0.094	 0.11
 73266	14 58 24.265	-37 21 44.90	 7.254	      	224.60116218	-37.36241844	  -19.55	  -22.39	B9V                      	 7.245	 0.018	 7.300	 0.044	 7.281	 0.023	-0.026	 0.00
 73341	14 59 13.925	-37 52 52.43	 6.508	      	224.80807925	-37.88118288	  -18.86	  -19.55	B8V                      	 6.598	 0.020	 6.689	 0.024	 6.666	 0.026	-0.080	-0.06
 73345	14 59 19.296	-51 34 34.08	 6.810	      	224.83044360	-51.57610415	  -11.14	  -12.00	B5V                      	 6.819	 0.027	 6.875	 0.033	 6.831	 0.021	-0.051	-0.03
 73500	15 01 22.600	-71 29 26.92	 6.762	      	225.34426527	-71.49076192	  -12.87	  -20.76	B5V                       	 6.775	 0.029	 6.809	 0.051	 6.828	 0.026	-0.078	-0.06
 74093	15 08 30.292	-66 28 33.05	 7.240	      	227.12628932	-66.47581073	  -12.23	  -15.15	B8V                       	 7.106	 0.024	 7.122	 0.024	 7.126	 0.017	 0.018	 0.04
 74220	15 10 00.611	-41 10 45.85	 7.525	      	227.50259081	-41.17938152	  -14.04	   -9.11	B9V                      	 7.521	 0.019	 7.598	 0.026	 7.571	 0.023	-0.047	-0.03
 74401	15 12 20.952	-16 24 39.86	 7.367	      	228.08731591	-16.41106721	   -6.89	   -2.05	B9V                      	 7.356	 0.024	 7.369	 0.049	 7.404	 0.020	-0.008	 0.01
 75467	15 25 00.010	-76 31 28.59	 7.204	      	231.25017759	-76.52457856	  -13.17	  -12.60	B9V                       	 7.138	 0.032	 7.189	 0.040	 7.139	 0.033	-0.004	 0.02
 76071	15 32 10.332	-21 58 00.57	 7.192	*     	233.04307761	-21.96677274	  -11.30	  -21.60	B9V                      	 7.107	 0.056	 7.074	 0.034	 6.992	 0.018	 0.031	 0.05
 76442	15 36 44.009	-41 03 37.64	 7.600	      	234.18341661	-41.06042469	  -13.64	  -12.65	B9V                      	 7.655	 0.019	 7.698	 0.047	 7.684	 0.023	-0.026	 0.00
 76591	15 38 32.638	-39 09 38.51	 6.622	      	234.63605657	-39.16064207	  -20.77	  -22.68	B9V                      	 6.683	 0.024	 6.739	 0.040	 6.763	 0.026	-0.069	-0.05
 76606	15 38 41.594	-45 42 31.56	 7.019	      	234.67334083	-45.70873226	   -9.80	  -14.30	B5V                      	 7.071	 0.026	 7.129	 0.029	 7.139	 0.026	-0.078	-0.06
 76633	15 39 00.057	-19 43 57.21	 7.581	      	234.75027841	-19.73251011	  -15.40	  -19.66	B9V                      	 7.476	 0.024	 7.489	 0.023	 7.492	 0.023	 0.047	 0.06
 77323	15 47 09.749	+30 33 56.32	 7.830	      	236.79065429	+30.56569777	  -12.56	  -21.98	B9V                       	 7.852	 0.018	 7.904	 0.036	 7.916	 0.027	-0.057	-0.04
 77523	15 49 43.104	-32 48 29.82	 7.439	      	237.42963985	-32.80822969	  -13.89	  -22.25	B9V                      	 7.387	 0.023	 7.393	 0.026	 7.416	 0.027	 0.010	 0.03
 77673	15 51 27.408	-42 18 02.57	 8.190	      	237.86420647	-42.30070773	   -2.03	   -2.34	B9V                      	 7.950	 0.024	 7.964	 0.047	 7.922	 0.031	 0.063	 0.07
 77677	15 51 29.838	-20 35 14.46	 7.621	      	237.87433397	-20.58734028	   -2.96	   -4.18	B9V                      	 7.392	 0.019	 7.389	 0.038	 7.344	 0.023	 0.078	 0.09
 77722	15 52 03.102	-70 49 16.01	 7.979	      	238.01298327	-70.82109215	   -7.66	   -8.41	B8V                       	 7.896	 0.027	 7.928	 0.034	 7.926	 0.026	-0.033	-0.01
 77752	15 52 35.067	-01 01 52.85	 7.799	      	238.14614875	-01.03128559	  -15.35	  -24.81	B9V                      	 7.661	 0.030	 7.639	 0.040	 7.604	 0.034	 0.165	 0.18
 77761	15 52 40.455	-79 24 13.86	 7.628	      	238.16865858	-79.40381536	   -7.23	  -13.76	B8V                       	 7.472	 0.018	 7.495	 0.026	 7.530	 0.027	 0.044	 0.06
 77800	15 53 11.695	-65 00 10.50	 7.767	      	238.29879707	-65.00286426	  -11.93	  -21.91	B9V                       	 7.742	 0.026	 7.817	 0.059	 7.773	 0.033	 0.004	 0.02
 77855	15 53 52.704	-78 09 31.31	 7.968	      	238.46975331	-78.15867924	  -13.03	   -7.31	B9V                       	 7.915	 0.024	 7.979	 0.047	 7.958	 0.034	 0.011	 0.03
 77918	15 54 44.959	-72 37 44.80	 7.954	      	238.68741542	-72.62908020	  -10.78	  -12.40	B9V                       	 7.912	 0.021	 7.919	 0.040	 7.911	 0.027	-0.035	-0.01
 77932	15 54 56.239	-53 29 01.88	 7.084	      	238.73437453	-53.48382659	  -11.06	  -11.41	B8V                       	 6.936	 0.021	 7.013	 0.051	 6.950	 0.023	 0.013	 0.03
 78197	15 58 05.341	-57 08 51.41	 7.703	      	239.52232625	-57.14754499	  -16.14	  -28.28	B9V                       	 7.478	 0.023	 7.488	 0.049	 7.433	 0.034	 0.092	 0.10
 78215	15 58 19.745	-41 39 34.61	 7.760	      	239.58229689	-41.65959528	   -7.71	   -7.72	B9V                      	 7.337	 0.020	 7.340	 0.042	 7.257	 0.029	 0.166	 0.18
 78357	15 59 54.776	-46 17 56.81	 7.538	      	239.97830083	-46.29903688	  -18.87	  -31.69	B9V                      	 7.268	 0.023	 7.271	 0.038	 7.182	 0.020	 0.164	 0.18
 78643	16 03 13.985	-60 24 21.39	 7.984	      	240.80828337	-60.40593584	   -2.57	   -2.74	B9V                       	 7.867	 0.027	 7.924	 0.067	 7.863	 0.018	 0.028	 0.04
 78702	16 04 00.239	-19 46 02.92	 7.668	      	241.00101908	-19.76742667	   -9.63	  -21.22	B9V                      	 7.379	 0.021	 7.340	 0.033	 7.237	 0.017	 0.122	 0.14
 78968	16 07 14.929	-17 56 09.73	 7.605	*     	241.81222176	-17.93598366	   -7.02	  -21.78	B9V                      	 7.435	 0.034	 7.457	 0.044	 7.401	 0.023	 0.189	 0.21
 79044	16 08 04.380	-36 13 54.61	 6.775	*     	242.01830039	-36.23176401	  -16.58	  -29.22	B9V                      	 6.829	 0.023	 6.946	 0.065	 6.913	 0.026	-0.056	-0.03
 79056	16 08 11.715	-77 17 20.25	 7.448	      	242.04890719	-77.28892844	   -8.65	  -11.95	B8V                       	 7.524	 0.021	 7.554	 0.033	 7.562	 0.024	-0.039	-0.02
 79160	16 09 22.722	-12 22 33.57	 7.407	      	242.34467945	-12.37599080	   -0.96	   -0.74	B9V                      	 7.185	 0.024	 7.193	 0.031	 7.147	 0.023	 0.117	 0.13
 79439	16 12 44.101	-19 30 10.34	 7.453	      	243.18376858	-19.50281430	   -6.21	  -23.86	B9V                      	 7.051	 0.018	 7.050	 0.049	 6.941	 0.024	 0.145	 0.16
 79470	16 13 06.160	-48 45 20.19	 7.878	      	243.27570242	-48.75558073	   -9.73	  -11.78	B9V                      	 7.540	 0.029	 7.482	 0.034	 7.449	 0.031	 0.165	 0.18
 79739	16 16 25.171	-24 59 19.49	 7.738	*     	244.10491703	-24.98868674	  -13.70	  -24.90	B8V                       	 7.240	 0.019	 7.174	 0.036	 7.025	 0.018	 0.197	 0.22
 79771	16 16 50.625	-25 51 46.71	 8.082	*     	244.21096850	-25.86291856	  -10.80	  -23.43	B9V                      	 7.325	 0.019	 7.190	 0.029	 7.098	 0.021	 0.309	 0.35
 79897	16 18 28.257	-23 16 27.49	 7.374	      	244.61776682	-23.27423885	  -11.13	  -26.75	B9V                      	 7.078	 0.024	 7.033	 0.036	 7.012	 0.020	 0.135	 0.15
 80493	16 25 50.660	-26 34 06.37	 7.843	      	246.46111308	-26.56838101	  -10.30	  -22.30	B9V                      	 7.298	 0.020	 7.175	 0.046	 7.076	 0.017	 0.246	 0.28
 81208	16 35 13.839	-35 43 28.71	 6.648	      	248.80769301	-35.72458243	  -10.42	  -24.64	B9V                      	 6.731	 0.026	 6.773	 0.051	 6.768	 0.029	-0.049	-0.03
 81316	16 36 28.673	-40 18 10.93	 7.028	*     	249.11950832	-40.30298210	  -12.20	  -22.00	B9V                      	 6.744	 0.023	 6.781	 0.033	 6.714	 0.016	 0.087	 0.10
 81368	16 37 02.646	-38 40 34.37	 7.318	      	249.26106039	-38.67616886	  -11.99	  -19.01	B9V                      	 7.268	 0.021	 7.273	 0.038	 7.233	 0.018	 0.005	 0.03
 81493	16 38 42.227	-68 43 15.14	 7.260	      	249.67605096	-68.72080003	  -15.81	  -29.62	B9V                       	 7.290	 0.029	 7.331	 0.038	 7.341	 0.029	-0.048	-0.03
 81891	16 43 38.723	-32 06 21.39	 6.510	      	250.91137366	-32.10588894	   -9.11	  -22.12	B8V                      	 6.578	 0.019	 6.674	 0.051	 6.630	 0.029	-0.076	-0.06
 82203	16 47 37.764	+37 33 36.80	 7.176	      	251.90736968	+37.56023144	   -7.05	   -3.81	B9V                       	 7.217	 0.021	 7.283	 0.018	 7.300	 0.017	-0.034	-0.01
 82594	16 53 03.766	-47 14 25.02	 7.533	      	253.26571689	-47.24025917	   -7.37	   -9.94	B8V                      	 7.198	 0.019	 7.201	 0.038	 7.171	 0.031	 0.123	 0.07
 82658	16 53 49.697	-70 10 15.51	 7.306	      	253.45710910	-70.17094950	   -5.21	  -10.66	B5V                       	 7.413	 0.023	 7.449	 0.029	 7.520	 0.020	-0.103	-0.09
 82670	16 53 59.372	-51 32 04.50	 8.167	      	253.49738603	-51.53457800	   -1.18	   -1.91	B5V                      	 7.769	 0.026	 7.776	 0.047	 7.722	 0.026	 0.068	 0.08
 83570	17 04 46.679	-50 04 16.97	 7.915	      	256.19446189	-50.07135749	    8.61	   -9.82	B9V                      	 7.513	 0.024	 7.541	 0.027	 7.461	 0.024	 0.183	 0.20
 83764	17 07 08.638	+09 00 32.17	 7.230	      	256.78600133	+09.00895061	   -3.88	   -5.47	B9V                       	 7.115	 0.027	 7.108	 0.026	 7.082	 0.021	 0.033	 0.05
 83943	17 09 29.940	-47 15 39.07	 7.687	      	257.37474952	-47.26083254	   -0.42	   -8.00	B8V                      	 7.406	 0.018	 7.395	 0.036	 7.381	 0.026	 0.078	 0.09
 84086	17 11 25.783	-50 07 08.85	 7.394	      	257.85742966	-50.11910866	   -0.08	   -6.99	B8V                      	 7.168	 0.023	 7.142	 0.040	 7.106	 0.026	 0.044	 0.06
 84190	17 12 35.029	-15 09 48.85	 7.810	      	258.14599122	-15.16353183	  -14.00	  -15.40	B9V                      	 7.509	 0.020	 7.492	 0.029	 7.469	 0.016	 0.135	 0.15
 84292	17 13 57.366	-32 14 28.49	 7.815	      	258.48902805	-32.24124885	   -0.86	    0.22	B8V                      	 7.494	 0.024	 7.478	 0.051	 7.433	 0.026	 0.125	 0.14
 84519	17 16 38.903	-60 57 22.66	 7.438	      	259.16215015	-60.95626674	  -10.64	  -11.31	B8V                       	 7.396	 0.023	 7.463	 0.024	 7.449	 0.027	-0.031	-0.01
 84628	17 18 01.372	-43 34 39.74	 7.018	      	259.50574072	-43.57765339	   -7.28	  -21.24	B8V                      	 7.079	 0.026	 7.115	 0.042	 7.122	 0.029	-0.040	-0.02
 84942	17 21 35.194	-40 21 34.56	 8.055	      	260.39666957	-40.35958048	   -8.31	   -7.89	B9V                      	 7.749	 0.021	 7.719	 0.029	 7.668	 0.021	 0.154	 0.17
 84967	17 21 58.879	-51 51 01.52	 7.930	      	260.49536324	-51.85037914	   -8.21	  -17.40	B9V                      	 7.826	 0.023	 7.861	 0.033	 7.815	 0.036	 0.026	 0.04
 84982	17 22 09.122	-30 30 04.86	 7.124	      	260.53802146	-30.50132812	   -4.72	   -9.00	B8V                      	 6.832	 0.023	 6.855	 0.055	 6.834	 0.027	 0.073	 0.08
 85138	17 23 57.624	-65 42 07.68	 6.671	      	260.99010512	-65.70210358	   -1.11	  -12.75	B5V                       	 6.684	 0.023	 6.737	 0.021	 6.732	 0.033	-0.074	-0.05
 85497	17 28 21.131	-52 38 05.55	 7.972	      	262.08807053	-52.63482496	   -5.78	  -20.80	B9V                      	 7.828	 0.027	 7.859	 0.040	 7.787	 0.021	 0.093	 0.11
 85803	17 31 56.548	-30 24 04.36	 8.166	      	262.98561518	-30.40119695	    0.94	   -6.05	B6V                      	 7.981	 0.021	 7.984	 0.026	 7.973	 0.023	 0.044	 0.06
 86507	17 40 43.015	-27 53 34.99	 8.048	      	265.17921362	-27.89300970	    5.13	  -17.92	B9V                      	 7.690	 0.021	 7.677	 0.061	 7.566	 0.023	 0.195	 0.21
 86850	17 44 43.839	-46 02 33.40	 6.697	      	266.18262932	-46.04258932	    9.94	   -9.00	B9V                      	 6.637	 0.021	 6.664	 0.031	 6.649	 0.031	-0.008	 0.01
 86880	17 45 02.111	-35 31 54.13	 7.056	      	266.25879236	-35.53162311	    1.02	  -33.21	B9V                      	 7.101	 0.027	 7.151	 0.036	 7.123	 0.017	-0.043	-0.02
 86944	17 45 57.069	+05 41 39.96	 7.546	      	266.48778234	+05.69445634	    1.78	   -8.96	B5V                       	 7.522	 0.023	 7.598	 0.026	 7.587	 0.023	-0.005	 0.02
 87140	17 48 15.075	-35 53 43.08	 7.100	      	267.06284681	-35.89523952	  -12.10	  -24.38	B9V                      	 7.194	 0.020	 7.236	 0.029	 7.284	 0.024	-0.042	-0.02
 87790	17 56 01.181	+05 09 41.25	 7.415	      	269.00492043	+05.16147659	   -0.49	   -7.35	B5V                       	 7.309	 0.026	 7.352	 0.027	 7.409	 0.017	-0.053	-0.03
 88121	17 59 53.965	-01 09 56.51	 8.412	      	269.97484603	-01.16571078	    2.80	    5.20	B8V                      	 7.920	 0.019	 7.888	 0.034	 7.847	 0.016	 0.236	 0.26
 88246	18 01 11.313	-40 20 07.87	 7.822	      	270.29713073	-40.33550396	    2.30	   -6.89	B8V                      	 7.853	 0.019	 7.919	 0.026	 7.920	 0.018	-0.084	-0.06
 88376	18 02 47.456	-01 20 10.98	 7.848	      	270.69775161	-01.33634765	   -7.45	  -15.24	B9V                      	 7.488	 0.027	 7.448	 0.047	 7.377	 0.023	 0.136	 0.15
 88681	18 06 13.034	+01 34 57.70	 7.924	      	271.55432230	+01.58273277	   -6.14	  -15.21	B9V                      	 7.835	 0.030	 7.885	 0.057	 7.863	 0.033	 0.007	 0.03
 88753	18 07 06.081	-01 46 13.86	 7.760	      	271.77534329	-01.77047704	   -2.03	  -15.98	B8V                      	 7.503	 0.026	 7.459	 0.033	 7.394	 0.031	 0.393	 0.46
 88903	18 08 53.546	-42 39 25.33	 7.186	      	272.22309990	-42.65702458	    2.81	   -4.59	B7V                      	 7.267	 0.024	 7.372	 0.044	 7.360	 0.031	-0.106	-0.09
 88914	18 08 59.100	-31 09 36.14	 7.956	      	272.24624817	-31.15998954	    0.61	  -20.10	B9V                      	 7.851	 0.020	 7.878	 0.042	 7.860	 0.021	 0.012	 0.03
 89022	18 10 05.769	-45 54 14.30	 7.501	      	272.52400296	-45.90394326	    9.83	  -11.94	B9V                      	 7.476	 0.026	 7.513	 0.031	 7.520	 0.027	-0.027	-0.01
 89026	18 10 10.137	+82 56 23.42	 7.501	      	272.54234506	+82.93976358	   -5.41	   31.26	B8V                       	 7.559	 0.026	 7.655	 0.026	 7.672	 0.024	-0.107	-0.09
 89338	18 13 42.915	-75 33 02.61	 7.090	      	273.42883648	-75.55067128	   -2.41	  -22.06	B9V                       	 6.986	 0.018	 7.036	 0.017	 7.034	 0.033	 0.003	 0.02
 89376	18 14 20.919	-41 54 33.25	 7.899	      	273.58715350	-41.90920499	    2.18	  -12.40	B9V                      	 7.873	 0.027	 7.948	 0.033	 7.940	 0.029	-0.032	-0.01
 89486	18 15 40.183	-33 05 29.65	 6.904	      	273.91743447	-33.09152791	   -1.32	  -16.84	B9V                      	 6.819	 0.023	 6.847	 0.034	 6.777	 0.023	 0.013	 0.03
 89500	18 15 50.442	-43 10 07.48	 7.020	      	273.96016746	-43.16872363	    2.15	   -8.27	B9V                      	 6.865	 0.026	 6.934	 0.046	 6.845	 0.018	-0.004	 0.02
 89852	18 20 09.010	-34 46 28.85	 7.907	      	275.03754646	-34.77466265	   -1.89	   -7.37	B8V                      	 7.867	 0.020	 7.896	 0.036	 7.973	 0.038	-0.050	-0.03
 89941	18 21 06.164	+20 56 05.46	 7.406	      	275.27568022	+20.93481815	    1.19	   13.26	B9V                       	 7.266	 0.021	 7.313	 0.029	 7.290	 0.018	 0.056	 0.07
 89960	18 21 16.450	-30 56 29.28	 6.954	      	275.31855038	-30.94142768	   -2.70	  -16.50	B6V                      	 6.813	 0.023	 6.817	 0.034	 6.805	 0.020	 0.023	 0.04
 90263	18 25 02.945	+14 08 41.88	 7.888	      	276.26226686	+14.14499724	    1.20	  -13.10	B7V                       	 7.791	 0.024	 7.821	 0.026	 7.825	 0.027	 0.020	 0.04
 90271	18 25 08.876	+05 05 04.43	 6.700	      	276.28698210	+05.08455362	    0.35	    3.83	B8V                       	 6.564	 0.021	 6.574	 0.026	 6.561	 0.026	 0.011	 0.03
 90315	18 25 40.179	+04 37 08.82	 8.222	      	276.41740386	+04.61913772	    3.04	   -8.43	B9V                      	 7.935	 0.023	 7.955	 0.042	 7.896	 0.026	 0.180	 0.20
 90639	18 29 37.899	-33 56 02.32	 7.051	      	277.40792005	-33.93393369	   -1.91	  -17.91	B8V                      	 7.031	 0.018	 7.096	 0.026	 7.083	 0.018	-0.038	-0.02
 90671	18 30 02.067	-33 29 43.36	 7.716	      	277.50861034	-33.49535656	    1.21	   -8.27	B8V                      	 7.657	 0.021	 7.714	 0.033	 7.687	 0.017	 0.010	 0.03
 90958	18 33 17.836	+05 26 43.94	 7.460	      	278.32432335	+05.44555437	   -3.24	   -6.73	B8V                       	 7.112	 0.023	 7.137	 0.053	 7.035	 0.020	 0.189	 0.21
 91031	18 34 12.414	-07 42 44.36	 7.242	      	278.55172426	-07.71232055	   -0.54	   -0.87	B9V                      	 7.055	 0.026	 7.052	 0.034	 7.019	 0.031	 0.099	 0.11
 91338	18 37 48.453	+05 53 00.47	 6.673	      	279.45187505	+05.88346886	    4.49	   -1.70	B8V                       	 6.615	 0.023	 6.683	 0.027	 6.662	 0.016	-0.026	 0.00
 91568	18 40 21.759	+26 07 51.13	 6.806	      	280.09066171	+26.13086185	    0.83	    3.61	B9V                       	 6.754	 0.023	 6.784	 0.059	 6.769	 0.018	 0.019	 0.04
 91705	18 42 06.239	+04 02 03.63	 7.919	      	280.52599616	+04.03436977	   -0.39	  -11.52	B9V                      	 7.793	 0.023	 7.811	 0.027	 7.815	 0.018	 0.086	 0.10
 91723	18 42 14.418	-81 48 29.21	 6.342	      	280.55983914	-81.80807274	   13.82	  -16.89	B8V                       	 6.505	 0.027	 6.556	 0.047	 6.556	 0.027	-0.104	-0.09
 91744	18 42 30.004	-70 18 11.40	 7.238	      	280.62502709	-70.30312131	   -1.44	  -18.29	B9V                       	 7.232	 0.021	 7.287	 0.047	 7.280	 0.029	-0.024	 0.00
 92188	18 47 19.036	-37 32 55.23	 7.083	      	281.82931018	-37.54860682	    2.57	  -28.53	B9V                      	 7.113	 0.024	 7.173	 0.044	 7.111	 0.031	-0.043	-0.02
 92541	18 51 29.543	+45 08 01.38	 7.282	      	282.87309623	+45.13371882	    0.13	   -0.46	B8V                       	 7.315	 0.026	 7.407	 0.026	 7.402	 0.023	-0.085	-0.07
 92594	18 52 02.207	+59 40 01.33	 6.978	      	283.00922002	+59.66701789	   -5.44	    7.38	B9V                       	 6.925	 0.023	 6.975	 0.020	 6.951	 0.017	-0.048	-0.03
 92648	18 52 40.307	+04 03 11.76	 7.816	      	283.16794049	+04.05326960	    2.64	   -1.23	B8V                      	 7.577	 0.024	 7.562	 0.023	 7.521	 0.021	 0.172	 0.19
 92691	18 53 13.741	+38 55 52.02	 7.821	      	283.30724842	+38.93112145	    2.12	   -1.54	B9V                       	 7.864	 0.021	 7.962	 0.020	 7.960	 0.020	-0.080	-0.06
 92825	18 54 48.260	+15 20 33.64	 7.057	      	283.70108621	+15.34270073	   -0.33	   -9.62	B9V                       	 6.954	 0.020	 6.986	 0.016	 6.976	 0.020	 0.002	 0.02
 92851	18 55 14.882	+32 24 00.58	 7.656	      	283.81200775	+32.40017539	    0.09	   -5.44	B8V                       	 7.615	 0.018	 7.670	 0.020	 7.674	 0.023	-0.049	-0.03
 92943	18 56 09.904	+07 56 08.22	 7.949	      	284.04127142	+07.93562685	   -2.37	   -4.24	B9V                       	 7.762	 0.026	 7.772	 0.029	 7.722	 0.024	 0.172	 0.19
 93004	18 56 47.200	-14 01 40.76	 7.697	      	284.19665513	-14.02796211	    3.83	  -11.09	B9V                      	 7.525	 0.020	 7.569	 0.034	 7.499	 0.027	 0.085	 0.12
 93161	18 58 33.880	+60 40 02.35	 6.924	      	284.64113177	+60.66724815	    7.26	   29.07	B8V                       	 6.894	 0.021	 6.987	 0.033	 6.942	 0.029	-0.038	-0.02
 93210	18 59 12.292	+39 13 02.36	 6.558	      	284.80121719	+39.21732415	   -0.44	   -0.62	B5V                       	 6.748	 0.020	 6.851	 0.021	 6.925	 9.995	-0.168	-0.17
 93799	19 06 09.414	-31 41 43.01	 8.171	      	286.53923577	-31.69524897	   -4.10	  -13.10	B9V                      	 7.987	 0.019	 7.982	 0.031	 7.948	 0.023	 0.035	 0.05
 94009	19 08 24.464	+13 05 52.72	 7.231	      	287.10192970	+13.09800057	    1.43	   -9.89	B5V                       	 7.223	 0.021	 7.300	 0.024	 7.300	 0.016	 0.010	 0.03
 94033	19 08 39.614	-39 57 36.42	 7.954	      	287.16500267	-39.96009360	   18.02	   -9.76	B9V                      	 7.903	 0.019	 7.999	 0.040	 7.960	 0.021	-0.019	 0.00
 94122	19 09 34.704	-23 11 27.53	 7.743	      	287.39460091	-23.19096160	   -0.40	   -7.40	B8V                      	 7.659	 0.023	 7.669	 0.038	 7.656	 0.026	 0.033	 0.05
 94250	19 11 06.432	+05 16 28.81	 7.016	      	287.77678920	+05.27465798	    5.21	    4.39	B9V                       	 6.840	 0.023	 6.831	 0.026	 6.800	 0.017	 0.060	 0.07
 94378	19 12 34.542	-37 31 26.54	 7.049	      	288.14392459	-37.52399759	   -0.13	  -16.43	B5V                      	 6.756	 0.024	 6.777	 0.047	 6.697	 0.017	 0.087	 0.10
 94588	19 14 58.106	+10 24 33.85	 7.375	      	288.74210025	+10.40940732	    3.33	   -2.29	B8V                       	 7.258	 0.024	 7.346	 0.034	 7.304	 0.033	-0.004	 0.02
 94592	19 14 58.848	+27 57 39.94	 6.946	      	288.74518618	+27.96108453	    5.56	    4.59	B5V                       	 6.942	 0.017	 7.054	 0.021	 7.088	 0.029	-0.068	-0.05
 94669	19 15 50.135	+37 17 56.49	 7.853	      	288.95889673	+37.29904442	   -0.27	   -8.49	B8V                       	 7.882	 0.027	 7.947	 0.023	 7.954	 0.024	-0.081	-0.06
 94787	19 17 11.174	+22 25 33.80	 7.792	      	289.29655831	+22.42608014	    0.72	  -10.62	B9V                       	 7.559	 0.020	 7.601	 0.027	 7.572	 0.017	 0.120	 0.13
 94849	19 17 59.174	-47 04 28.48	 7.325	      	289.49656729	-47.07454739	   -2.17	  -11.97	B8V                      	 7.395	 0.020	 7.475	 0.031	 7.450	 0.021	-0.085	-0.07
 94925	19 18 59.097	-10 55 47.64	 8.191	      	289.74622779	-10.92987881	    3.12	   -8.34	B9V                      	 7.950	 0.027	 7.970	 0.044	 7.949	 0.023	 0.062	 0.07
 94936	19 19 05.028	+10 02 44.53	 8.249	      	289.77094582	+10.04570453	    1.24	   -1.20	B9V                       	 7.909	 0.023	 7.915	 0.024	 7.878	 0.024	 0.200	 0.22
 95051	19 20 25.539	+32 05 56.13	 6.910	      	290.10641259	+32.09893599	    0.62	   -4.43	B7V                       	 7.018	 0.023	 7.143	 0.024	 7.129	 0.023	-0.103	-0.09
 95109	19 20 54.300	+22 11 55.62	 6.587	      	290.22625378	+22.19880725	   -0.95	   -9.46	B8V                       	 6.630	 0.019	 6.688	 0.016	 6.697	 0.021	-0.063	-0.04
 95204	19 22 03.884	+17 45 12.18	 7.014	      	290.51617800	+17.75340570	    1.68	   -9.41	B5V                       	 6.835	 0.020	 6.880	 0.031	 6.855	 0.021	 0.040	 0.06
 95384	19 24 12.700	+18 44 28.20	 7.870	      	291.05291115	+18.74119745	    2.45	  -13.10	B8V                       	 7.852	 0.020	 7.924	 0.018	 7.934	 0.017	 0.007	 0.03
 95400	19 24 22.539	+28 05 15.25	 6.570	*     	291.09391474	+28.08758400	   -0.08	   -5.99	B5V                       	 6.596	 0.026	 6.705	 0.026	 6.719	 0.023	-0.080	-0.06
 95404	19 24 26.297	-55 53 17.95	 7.507	      	291.10955068	-55.88829466	    4.48	  -10.74	B8V                       	 7.589	 0.024	 7.682	 0.033	 7.624	 0.026	-0.047	-0.03
 95511	19 25 38.103	-02 03 40.01	 7.682	      	291.40872722	-02.06113159	   14.94	    7.82	B9V                      	 7.449	 0.044	 7.451	 0.046	 7.388	 0.042	 0.124	 0.14
 95543	19 26 01.214	+45 00 47.12	 7.196	      	291.50505294	+45.01307384	    2.11	    6.32	B5V                       	 7.331	 0.020	 7.464	 0.023	 7.534	 0.023	-0.151	-0.15
 95707	19 28 02.761	-01 20 18.78	 8.141	      	292.01149953	-01.33854759	    2.17	   -1.43	B9V                      	 7.819	 0.024	 7.762	 0.024	 7.739	 0.024	 0.181	 0.20
 95884	19 30 02.155	-15 58 32.24	 7.593	      	292.50895741	-15.97559692	    9.28	  -10.96	B9V                      	 7.372	 0.024	 7.329	 0.049	 7.271	 0.023	 0.109	 0.12
 96348	19 35 21.844	+34 41 16.81	 7.205	      	293.84101871	+34.68800425	   -0.92	   -0.62	B5V                       	 7.275	 0.021	 7.373	 0.017	 7.384	 0.018	-0.100	-0.08
 96430	19 36 16.905	+33 27 41.05	 7.363	      	294.07043220	+33.46140348	    2.49	   -0.41	B7V                       	 7.435	 0.021	 7.513	 0.017	 7.510	 0.018	-0.089	-0.07
 96736	19 39 52.285	-15 10 02.77	 6.752	      	294.96783585	-15.16737530	    7.58	  -25.48	B8V                       	 6.788	 0.027	 6.887	 0.040	 6.836	 0.026	-0.050	-0.03
 96784	19 40 22.541	+16 20 00.09	 7.378	      	295.09392694	+16.33338188	   -1.64	   -9.19	B8V                       	 7.198	 0.018	 7.270	 0.038	 7.269	 0.018	 0.036	 0.05
 97117	19 44 15.854	+07 35 17.60	 8.070	      	296.06605384	+07.58822827	    2.16	   -2.37	B6V                       	 7.963	 0.026	 7.906	 0.053	 7.808	 0.031	 0.051	 0.06
 97403	19 47 50.109	-00 03 49.27	 8.088	      	296.95878362	-00.06367796	    1.00	   -3.60	B8V                      	 7.964	 0.023	 7.974	 0.031	 7.991	 0.024	 0.132	 0.01
 97503	19 49 04.040	+53 46 02.96	 7.153	      	297.26676593	+53.76747318	   16.11	    6.73	B8V                       	 7.201	 0.021	 7.300	 0.016	 7.330	 0.017	-0.101	-0.08
 97818	19 52 38.833	+18 44 26.48	 7.698	      	298.16180880	+18.74069939	   -1.85	   -4.17	B8V                       	 7.658	 0.023	 7.744	 0.047	 7.732	 0.020	-0.041	-0.02
 97907	19 53 47.301	+34 35 01.76	 7.084	      	298.44708352	+34.58382517	    1.71	   -1.64	B8V                       	 7.141	 0.029	 7.267	 0.026	 7.234	 0.016	-0.110	-0.09
 98094	19 56 08.791	+33 29 34.30	 7.568	      	299.03662773	+33.49286677	    1.10	   -2.56	B7V                       	 7.660	 0.030	 7.745	 0.016	 7.778	 0.016	-0.080	-0.06
 98124	19 56 33.630	+08 15 21.32	 7.503	      	299.14012946	+08.25595428	   -1.04	  -12.67	B5V                       	 7.573	 0.018	 7.634	 0.023	 7.652	 0.018	-0.058	-0.04
 98186	19 57 10.654	+30 51 22.75	 7.534	      	299.29438060	+30.85631955	    4.31	    0.38	B8V                       	 7.520	 0.023	 7.607	 0.017	 7.615	 0.018	-0.051	-0.03
 98289	19 58 13.670	+34 25 21.92	 7.720	      	299.55694111	+34.42275637	    5.46	   -0.38	B6V                       	 7.817	 0.017	 7.917	 0.020	 7.941	 0.020	-0.070	-0.05
 98312	19 58 32.492	-63 07 40.77	 7.896	      	299.63535151	-63.12796346	    5.94	  -11.49	B9V                       	 7.874	 0.024	 7.907	 0.029	 7.928	 0.023	-0.038	-0.02
 98467	20 00 19.239	+29 49 17.45	 7.826	      	300.08015110	+29.82151736	    3.81	   -1.30	B8V                       	 7.874	 0.023	 7.980	 0.024	 7.968	 0.018	-0.081	-0.06
 98525	20 00 58.743	+31 13 49.66	 7.001	      	300.24475149	+31.23046526	    3.95	   -1.43	B7V                       	 7.085	 0.020	 7.122	 0.018	 7.200	 0.021	-0.106	-0.09
 98611	20 01 45.538	+57 39 06.50	 7.756	      	300.43972920	+57.65179291	    2.38	    5.16	B8V                       	 7.732	 0.024	 7.774	 0.024	 7.742	 0.027	-0.080	-0.06
 98630	20 01 55.547	+31 07 03.24	 6.660	      	300.48143249	+31.11755873	    4.23	    3.02	B7V                       	 6.608	 0.024	 6.659	 0.017	 6.664	 0.020	-0.076	-0.06
 98637	20 02 01.817	+35 19 56.91	 7.450	      	300.50756734	+35.33247825	    1.76	   -1.50	B8V                       	 7.453	 0.026	 7.579	 0.018	 7.575	 0.024	-0.075	-0.05
 98796	20 03 56.283	+31 07 25.61	 7.849	      	300.98449144	+31.12378192	    6.76	   -0.82	B7V                       	 7.817	 0.026	 7.896	 0.020	 7.885	 0.024	-0.050	-0.03
 98838	20 04 17.897	+31 56 09.50	 7.692	      	301.07455683	+31.93597521	    4.26	   -0.80	B7V                       	 7.711	 0.021	 7.796	 0.017	 7.832	 0.018	-0.057	-0.04
 99050	20 06 36.237	-04 25 02.80	 6.965	      	301.65099388	-04.41740206	   -2.99	  -17.96	B9V                      	 6.627	 0.023	 6.633	 0.047	 6.619	 0.031	 0.153	 0.17
 99193	20 08 13.000	-18 48 13.87	 7.030	      	302.05415908	-18.80382668	    2.74	  -11.16	B8V                      	 6.962	 0.019	 7.036	 0.038	 7.025	 0.023	-0.018	 0.00
 99359	20 10 01.650	+36 58 42.47	 7.741	      	302.50682783	+36.97844879	   14.88	    6.44	B9V                       	 7.577	 0.027	 7.606	 0.021	 7.569	 0.018	 0.030	 0.05
 99515	20 11 47.386	+40 19 48.00	 7.145	      	302.94743576	+40.32999829	    2.40	    0.78	B5V                       	 7.175	 0.029	 7.260	 0.021	 7.264	 0.017	-0.080	-0.06
 99539	20 12 03.747	+47 44 13.36	 6.987	      	303.01558754	+47.73704037	    6.47	    1.40	B7V                       	 7.092	 0.017	 7.167	 0.020	 7.213	 0.020	-0.110	-0.09
 99617	20 12 58.535	+27 17 03.87	 7.825	      	303.24389063	+27.28442743	    2.17	   -8.39	B7V                       	 7.820	 0.023	 7.855	 0.026	 7.901	 0.018	-0.062	-0.04
 99827	20 15 17.195	+45 44 27.73	 7.152	      	303.82164617	+45.74103020	    0.40	    2.10	B6V                       	 7.234	 0.018	 7.328	 0.016	 7.349	 0.020	-0.085	-0.07
 99974	20 16 56.755	+34 08 22.87	 7.848	      	304.23646715	+34.13968920	    3.85	   -1.81	B7V                       	 7.837	 0.020	 7.938	 0.024	 7.938	 0.020	-0.070	-0.05
 99997	20 17 12.527	+40 35 29.02	 7.133	      	304.30219385	+40.59139443	    0.54	    0.33	B8V                       	 7.009	 0.020	 7.044	 0.017	 7.047	 0.017	-0.021	 0.00
100196	20 19 23.542	-29 37 26.14	 7.664	      	304.84806620	-29.62391886	    9.61	   -3.15	B8V                      	 7.735	 0.020	 7.838	 0.034	 7.854	 0.027	-0.084	-0.06
100385	20 21 29.674	-10 08 39.16	 7.281	      	305.37361591	-10.14418995	   10.18	   -9.14	B9V                      	 7.172	 0.029	 7.206	 0.018	 7.181	 0.018	 0.027	 0.04
100666	20 24 38.300	+08 35 50.94	 6.725	      	306.15957298	+08.59750403	    4.08	   -8.03	B9V                       	 6.582	 0.017	 6.625	 0.029	 6.635	 0.020	 0.025	 0.04
100719	20 25 10.804	+21 29 18.84	 7.152	      	306.29501477	+21.48857220	   -0.02	   -2.50	B5V                       	 7.159	 0.019	 7.221	 0.023	 7.249	 0.018	-0.106	-0.09
100784	20 26 03.859	+40 24 06.16	 6.713	      	306.51605442	+40.40170383	    7.25	    3.01	B8V                       	 6.754	 0.029	 6.841	 0.017	 6.875	 0.016	-0.100	-0.08
100877	20 27 14.281	+43 08 50.84	 7.683	      	306.80948736	+43.14745268	    4.53	    1.50	B9V                       	 7.664	 0.019	 7.720	 0.018	 7.708	 0.018	-0.060	-0.04
101383	20 32 52.328	+43 11 29.66	 6.682	      	308.21802354	+43.19157534	    3.46	   -1.58	B5V                       	 6.749	 0.020	 6.859	 0.033	 6.868	 0.018	-0.112	-0.10
101799	20 37 48.922	-17 07 20.84	 7.102	      	309.45380604	-17.12241249	   14.02	  -17.37	B9V                      	 7.046	 0.019	 7.083	 0.044	 7.084	 0.023	-0.041	-0.02
102108	20 41 33.352	-27 59 41.62	 7.654	      	310.38890402	-27.99486518	   22.09	  -11.55	B9V                      	 7.712	 0.021	 7.801	 0.024	 7.773	 0.024	-0.062	-0.04
102309	20 43 47.672	+23 47 28.00	 6.932	      	310.94860255	+23.79111765	   10.98	   -3.03	B8V                       	 6.947	 0.024	 6.999	 0.020	 7.026	 0.021	-0.046	-0.02
102729	20 49 00.518	+38 51 54.41	 7.591	      	312.25214856	+38.86512126	    3.47	   -3.17	B8V                       	 7.622	 0.026	 7.726	 0.040	 7.706	 0.021	-0.107	-0.09
102858	20 50 18.250	+56 47 54.39	 7.150	      	312.57602477	+56.79843378	    4.12	    3.64	B8V                       	 7.199	 0.024	 7.285	 0.038	 7.278	 0.024	-0.069	-0.05
102987	20 51 57.351	+46 44 05.21	 7.555	      	312.98894631	+46.73477857	    4.28	    1.04	B6V                       	 7.583	 0.027	 7.694	 0.042	 7.725	 0.021	-0.070	-0.05
103018	20 52 16.099	-19 38 36.95	 7.295	      	313.06704980	-19.64356893	   11.55	  -11.58	B9V                      	 7.351	 0.018	 7.421	 0.026	 7.417	 0.021	-0.056	-0.03
103050	20 52 43.249	+56 35 05.86	 7.570	      	313.18018401	+56.58495175	    4.46	    3.93	B7V                       	 7.692	 0.023	 7.811	 0.038	 7.833	 0.023	-0.118	-0.10
103066	20 52 56.207	+29 19 54.92	 7.704	      	313.23418276	+29.33193432	    5.31	   -5.35	B9V                       	 7.693	 0.018	 7.703	 0.059	 7.736	 0.020	-0.042	-0.02
103322	20 55 59.007	+44 22 26.16	 6.855	      	313.99584918	+44.37392287	    4.46	    4.40	B9V                       	 6.817	 0.021	 6.843	 0.027	 6.839	 0.023	-0.047	-0.03
103341	20 56 11.596	+43 25 27.52	 6.945	      	314.04827991	+43.42430514	   10.45	    2.02	B6V                       	 7.045	 0.021	 7.121	 0.031	 7.161	 0.024	-0.108	-0.09
103343	20 56 12.789	+51 04 30.07	 6.669	      	314.05326737	+51.07501300	    4.97	    3.18	B5V                       	 6.725	 0.024	 6.827	 0.020	 6.847	 0.016	-0.097	-0.08
103509	20 58 15.307	+47 37 03.66	 7.576	      	314.56376916	+47.61767228	    2.57	    4.00	B5V                       	 7.653	 0.018	 7.760	 0.033	 7.766	 0.024	-0.102	-0.09
103548	20 58 43.700	+31 38 51.04	 7.189	      	314.68202579	+31.64748815	   20.46	    9.20	B9V                       	 7.166	 0.020	 7.250	 0.029	 7.255	 0.020	-0.044	-0.02
103823	21 02 21.768	+23 19 27.38	 7.376	      	315.59068587	+23.32429167	    5.43	   -7.45	B9V                       	 7.309	 0.020	 7.344	 0.031	 7.351	 0.018	 0.016	 0.04
103870	21 02 48.077	+21 48 35.90	 7.546	      	315.70030231	+21.80998764	    6.97	   -6.45	B8V                       	 7.533	 0.021	 7.575	 0.033	 7.603	 0.021	-0.048	-0.03
104136	21 05 56.249	+48 02 40.08	 7.534	      	316.48437828	+48.04446640	   -2.51	    0.24	B9V                       	 7.348	 0.027	 7.365	 0.042	 7.365	 0.029	 0.050	 0.06
104207	21 06 43.718	+48 11 20.65	 7.534	      	316.68213034	+48.18906182	    7.55	    3.60	B9V                       	 7.529	 0.019	 7.597	 0.038	 7.570	 0.016	 0.048	 0.06
104268	21 07 23.707	+47 16 39.06	 7.288	      	316.84872420	+47.27751483	   14.79	    0.82	B8V                       	 7.240	 0.018	 7.273	 0.018	 7.259	 0.023	-0.050	-0.03
104389	21 08 51.507	+01 47 15.15	 7.072	      	317.21457757	+01.78755800	   14.14	   -7.03	B9V                       	 7.101	 0.024	 7.183	 0.040	 7.144	 0.020	-0.058	-0.04
104508	21 10 10.004	-43 22 57.81	 6.619	      	317.54164008	-43.38269185	   12.52	  -13.43	B8V                      	 6.639	 0.018	 6.636	 0.029	 6.661	 0.020	-0.079	-0.06
104573	21 11 01.778	+55 19 55.98	 7.668	      	317.75740630	+55.33222730	    0.43	   -3.91	B8V                       	 7.488	 0.029	 7.471	 0.049	 7.488	 0.023	 0.064	 0.07
105001	21 15 57.912	+45 43 53.89	 7.808	      	318.99128514	+45.73163730	    3.70	   -0.75	B8V                       	 7.857	 0.021	 7.926	 0.029	 7.965	 0.029	-0.020	 0.00
105053	21 16 46.151	+05 15 07.77	 7.842	      	319.19225989	+05.25217717	   15.38	   -8.28	B9V                      	 7.739	 0.027	 7.773	 0.046	 7.709	 0.023	 0.010	 0.03
105153	21 18 02.910	+46 51 26.29	 7.086	      	319.51209509	+46.85729638	    8.04	    2.66	B9V                       	 7.132	 0.023	 7.195	 0.017	 7.230	 0.020	-0.087	-0.07
105240	21 19 01.784	+29 44 35.28	 7.300	      	319.75742820	+29.74314814	    2.08	   -6.24	B8V                       	 7.300	 0.019	 7.360	 0.020	 7.372	 0.020	-0.033	-0.01
105595	21 23 17.529	+39 20 58.76	 7.318	      	320.82299428	+39.34966707	   13.57	   -4.70	B9V                       	 7.339	 0.021	 7.454	 0.061	 7.381	 0.016	-0.024	 0.01
105610	21 23 25.261	+65 02 02.58	 7.328	      	320.85520319	+65.03405493	    8.74	   -2.13	B9V                       	 7.351	 0.027	 7.413	 0.031	 7.429	 0.027	-0.038	-0.02
105659	21 24 05.976	+48 33 24.84	 7.562	      	321.02492763	+48.55695422	   -7.57	  -22.51	B9V                       	 7.498	 0.030	 7.611	 0.036	 7.532	 0.024	-0.065	-0.04
105893	21 26 46.567	+43 48 44.41	 7.439	      	321.69403003	+43.81234317	   -0.29	   -2.69	B9V                       	 7.248	 0.023	 7.309	 0.042	 7.281	 0.020	 0.012	 0.03
106141	21 29 57.682	+32 48 36.37	 7.801	      	322.49033727	+32.81009849	    2.03	    1.22	B5V                       	 7.840	 0.021	 7.859	 0.017	 7.916	 0.021	-0.055	-0.03
106658	21 36 13.329	+50 40 44.67	 7.317	      	324.05552262	+50.67908352	    3.69	   -3.14	B8V                       	 7.404	 0.021	 7.554	 0.053	 7.524	 0.026	-0.086	-0.07
106768	21 37 37.674	-19 13 51.66	 7.502	      	324.40694241	-19.23101638	   12.63	    0.03	B8V                      	 7.591	 0.027	 7.635	 0.021	 7.655	 0.020	-0.085	-0.07
106790	21 37 48.668	+39 19 01.84	 6.758	      	324.45273091	+39.31717476	   17.34	    0.82	B9V                       	 6.745	 0.023	 6.759	 0.027	 6.823	 0.021	-0.035	-0.01
106834	21 38 17.021	-69 37 48.63	 6.830	      	324.57070166	-69.63011948	   31.09	  -22.34	B8V                       	 6.880	 0.023	 6.990	 0.053	 6.954	 0.021	-0.095	-0.08
106970	21 39 53.970	+44 25 55.71	 6.772	      	324.97484825	+44.43214460	    7.87	   -0.95	B9V                       	 6.706	 0.020	 6.767	 0.016	 6.753	 0.021	-0.053	-0.03
107159	21 42 21.092	+50 51 28.89	 7.262	      	325.58787584	+50.85803113	    1.56	   -1.96	B7V                       	 7.236	 0.021	 7.294	 0.059	 7.333	 0.027	-0.050	-0.03
107321	21 44 17.152	+49 16 08.54	 7.583	      	326.07143622	+49.26906140	    7.88	   -9.71	B7V                       	 7.667	 0.019	 7.737	 0.036	 7.796	 0.024	-0.090	-0.07
107495	21 46 19.464	+09 20 32.70	 7.729	      	326.58107582	+09.34241563	   10.53	    0.63	B7V                       	 7.810	 0.027	 7.849	 0.024	 7.879	 0.024	-0.076	-0.06
107690	21 48 54.434	-56 16 26.44	 6.592	      	327.22671581	-56.27400560	   20.75	   -1.72	B9V                       	 6.631	 0.024	 6.663	 0.036	 6.677	 0.023	-0.077	-0.06
107823	21 50 38.570	-83 57 39.60	 7.614	      	327.66083634	-83.96097106	   -5.52	  -11.92	B8V                       	 7.583	 0.023	 7.681	 0.023	 7.657	 0.020	-0.019	 0.00
108348	21 57 02.225	+48 40 06.83	 6.542	      	329.25925035	+48.66856408	    5.24	    0.48	B8V                       	 6.625	 0.026	 6.710	 0.047	 6.720	 0.017	-0.074	-0.05
108402	21 57 39.355	-08 33 51.55	 6.811	      	329.41395837	-08.56433053	    9.12	    4.87	B9V                      	 6.837	 0.024	 6.905	 0.044	 6.803	 0.021	-0.041	-0.02
108542	21 59 17.739	-23 50 00.29	 6.988	      	329.82382336	-23.83333502	   34.10	  -32.30	B9V                      	 6.970	 0.023	 6.976	 0.036	 6.984	 0.027	 0.026	 0.04
108864	22 03 14.461	+30 12 11.56	 7.034	      	330.81023837	+30.20319673	    6.11	    5.45	B9V                       	 7.030	 0.027	 7.074	 0.018	 7.071	 0.017	-0.042	-0.02
108879	22 03 20.890	+54 52 48.23	 7.088	      	330.83697777	+54.88005569	   15.09	    2.81	B9V                       	 7.102	 0.018	 7.173	 0.040	 7.159	 0.017	-0.046	-0.02
108885	22 03 24.412	+30 02 14.70	 7.490	      	330.85169348	+30.03743593	    8.74	   -7.92	B7V                       	 7.489	 0.020	 7.572	 0.020	 7.588	 0.017	-0.056	-0.03
108891	22 03 27.646	+49 39 53.56	 7.608	      	330.86516162	+49.66487530	    8.07	    1.17	B8V                       	 7.700	 0.029	 7.769	 0.024	 7.802	 0.018	-0.060	-0.04
108908	22 03 39.095	-29 20 47.61	 7.430	      	330.91285229	-29.34655954	   15.37	    0.02	B8V                      	 7.482	 0.020	 7.566	 0.036	 7.578	 0.021	-0.081	-0.06
109137	22 06 24.597	+25 09 04.99	 7.321	      	331.60246065	+25.15140708	   10.20	   -9.01	B8V                       	 7.362	 0.021	 7.436	 0.018	 7.440	 0.015	-0.073	-0.05
109218	22 07 31.356	+09 40 15.64	 7.103	      	331.88061103	+09.67102154	   16.06	   -4.62	B8V                       	 7.200	 0.029	 7.227	 0.047	 7.264	 0.026	-0.083	-0.06
109514	22 11 04.818	+48 40 38.58	 6.640	      	332.76999102	+48.67739193	   22.65	   -3.86	B9V                       	 6.666	 0.026	 6.772	 0.029	 6.759	 0.017	-0.046	-0.02
109591	22 12 01.802	+47 05 44.26	 6.697	      	333.00746102	+47.09561853	   13.82	    3.74	B9V                       	 6.641	 0.023	 6.635	 0.026	 6.707	 0.018	-0.024	 0.00
109724	22 13 35.093	+70 08 27.50	 8.089	      	333.39618824	+70.14097355	    4.39	    0.00	B9V                       	 7.943	 0.029	 7.954	 0.027	 7.923	 0.020	 0.081	 0.09
109942	22 16 00.645	+11 45 35.80	 7.308	      	334.00265570	+11.75996151	   12.63	   -7.23	B9V                       	 7.344	 0.030	 7.425	 0.040	 7.406	 0.027	-0.049	-0.03
110361	22 21 08.105	+48 14 23.97	 7.621	      	335.28374948	+48.24000301	    5.71	   -5.00	B9V                       	 7.539	 0.018	 7.598	 0.026	 7.580	 0.023	-0.010	 0.01
110408	22 21 50.871	+42 04 41.37	 6.428	      	335.46191316	+42.07816870	   15.33	   -4.50	B5V                       	 6.540	 0.039	 6.644	 0.024	 6.608	 0.020	-0.086	-0.07
110913	22 28 13.919	+24 47 33.39	 6.779	      	337.05797368	+24.79260375	    8.08	    2.18	B9V                       	 6.771	 0.018	 6.827	 0.021	 6.838	 0.021	-0.033	-0.01
112152	22 42 57.966	+27 59 19.05	 7.352	      	340.74149436	+27.98865202	   10.90	  -10.78	B8V                       	 7.317	 0.024	 7.405	 0.020	 7.408	 0.029	-0.060	-0.04
112850	22 51 13.318	+48 43 59.67	 6.923	      	342.80547835	+48.73324506	    3.48	   -1.33	B7V                       	 6.937	 0.021	 7.005	 0.020	 6.994	 0.021	-0.076	-0.06
113310	22 56 49.410	-10 15 46.70	 8.026	      	344.20580895	-10.26293360	   26.81	  -15.57	B9V                      	 7.831	 0.020	 7.811	 0.042	 7.771	 0.024	 0.127	 0.14
113316	22 56 56.135	+59 57 42.13	 7.232	      	344.23382924	+59.96169505	   13.75	    3.28	B7V                       	 7.312	 0.018	 7.395	 0.026	 7.416	 0.016	-0.050	-0.03
113505	22 59 12.845	+52 18 10.74	 6.979	      	344.80352555	+52.30300473	   -0.71	   -8.58	B7V                       	 6.927	 0.021	 7.001	 0.026	 6.998	 0.024	-0.035	-0.01
113851	23 03 21.133	+62 38 32.74	 8.107	      	345.83801388	+62.64243452	    7.65	   -2.90	B7V                       	 7.986	 0.020	 7.964	 0.020	 7.951	 0.021	 0.040	 0.06
114054	23 05 52.531	-07 56 12.17	 6.687	      	346.46884925	-07.93669589	   11.62	   -7.01	B9V                      	 6.614	 0.020	 6.674	 0.023	 6.614	 0.027	-0.009	 0.01
114344	23 09 28.410	+68 25 42.42	 8.001	*     	347.36834448	+68.42844724	    4.60	    1.30	B9V                       	 7.649	 0.020	 7.634	 0.040	 7.623	 0.020	 0.195	 0.21
114816	23 15 28.509	+64 16 00.16	 7.157	      	348.86874772	+64.26671683	    7.39	   -2.00	B5V                       	 7.131	 0.023	 7.218	 0.051	 7.220	 0.017	-0.015	 0.01
115098	23 18 46.048	-47 26 07.38	 6.601	      	349.69179558	-47.43537497	   20.35	   -2.91	B9V                      	 6.557	 0.020	 6.598	 0.031	 6.574	 0.026	-0.042	-0.02
115658	23 25 48.847	+59 40 01.06	 8.152	      	351.45356342	+59.66698469	   -6.99	   -9.89	B9V                       	 7.742	 0.021	 7.678	 0.026	 7.662	 0.018	 0.334	 0.39
117932	23 55 16.689	-31 53 03.38	 6.880	      	358.81948829	-31.88427403	   17.54	    1.26	B8V                       	 6.963	 0.018	 7.050	 0.044	 7.056	 0.021	-0.080	-0.06
[EOD]


# http://vizier.u-strasbg.fr//viz-bin/asu-acl?-source=yCat_5137